Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.))
Hi = hw+((Q*log((Rw/r),10))/(2.72*Tw))
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Initial Aquifer Thickness - (Measured in Meter) - Initial Aquifer Thickness is the aquifer thickness at initial stage before pumping.
Depth of Water - (Measured in Meter) - Depth of Water in the well measured above the impermeable layer.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of well - (Measured in Meter) - Radius of well is defined as the distance from center of well to its outer boundary.
Coefficient of Transmissibility in Enviro. Eng. - (Measured in Square Meter per Second) - Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
STEP 1: Convert Input(s) to Base Unit
Depth of Water: 2.44 Meter --> 2.44 Meter No Conversion Required
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of well: 7.5 Meter --> 7.5 Meter No Conversion Required
Coefficient of Transmissibility in Enviro. Eng.: 26.9 Square Meter per Second --> 26.9 Square Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Hi = hw+((Q*log((Rw/r),10))/(2.72*Tw)) --> 2.44+((1.01*log((8.6/7.5),10))/(2.72*26.9))
Evaluating ... ...
Hi = 2.67224262748466
STEP 3: Convert Result to Output's Unit
2.67224262748466 Meter --> No Conversion Required
FINAL ANSWER
2.67224262748466 2.672243 Meter <-- Initial Aquifer Thickness
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

9 Aquifer Thickness Calculators

Thickness of Confined Aquifer given Discharge in Confined Aquifer
Go Aquifer Thickness During Pumping = Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),e)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer
Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness given Depth of Water in Two Wells
Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility
Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Transmissibility in Enviro. Eng.))
Aquifer Thickness given Confined Aquifer Discharge
Go Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),e)))
Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10
Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),10)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer with Base 10
Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10
Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.))
Aquifer Thickness given Confined Aquifer Discharge with Base 10
Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10)))

Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 Formula

Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.))
Hi = hw+((Q*log((Rw/r),10))/(2.72*Tw))

What is Aquifer?

An aquifer is an underground layer of water-bearing permeable rock, rock fractures or unconsolidated materials (gravel, sand, or silt). Groundwater can be extracted using a water well.

How to Calculate Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10?

Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 calculator uses Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.)) to calculate the Initial Aquifer Thickness, The Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used. Initial Aquifer Thickness is denoted by Hi symbol.

How to calculate Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 using this online calculator? To use this online calculator for Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10, enter Depth of Water (hw), Discharge (Q), Radius of Influence (Rw), Radius of well (r) & Coefficient of Transmissibility in Enviro. Eng. (Tw) and hit the calculate button. Here is how the Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 calculation can be explained with given input values -> 2.672243 = 2.44+((1.01*log((8.6/7.5),10))/(2.72*26.9)).

FAQ

What is Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10?
The Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used and is represented as Hi = hw+((Q*log((Rw/r),10))/(2.72*Tw)) or Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.)). Depth of Water in the well measured above the impermeable layer, Discharge is the rate of flow of a liquid, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table, Radius of well is defined as the distance from center of well to its outer boundary & Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
How to calculate Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10?
The Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used is calculated using Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.)). To calculate Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10, you need Depth of Water (hw), Discharge (Q), Radius of Influence (Rw), Radius of well (r) & Coefficient of Transmissibility in Enviro. Eng. (Tw). With our tool, you need to enter the respective value for Depth of Water, Discharge, Radius of Influence, Radius of well & Coefficient of Transmissibility in Enviro. Eng and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Initial Aquifer Thickness?
In this formula, Initial Aquifer Thickness uses Depth of Water, Discharge, Radius of Influence, Radius of well & Coefficient of Transmissibility in Enviro. Eng. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))
  • Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness))
  • Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Transmissibility in Enviro. Eng.))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!