Assumed Grit Quantity given Volume of Aerated Grit Chamber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Assumed grit quantity = (Volume/Volumetric Flow Rate)
G = (VT/V)
This formula uses 3 Variables
Variables Used
Assumed grit quantity - Assumed grit quantity is a unit less quantity in terms of cubic meter per gallon.
Volume - (Measured in Cubic Meter) - Volume is the amount of space that a substance or object occupies or that is enclosed within a container.
Volumetric Flow Rate - (Measured in Cubic Meter per Second) - Volumetric Flow Rate is the volume of fluid which passes per unit time.
STEP 1: Convert Input(s) to Base Unit
Volume: 0.63 Cubic Meter --> 0.63 Cubic Meter No Conversion Required
Volumetric Flow Rate: 5 Cubic Meter per Second --> 5 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
G = (VT/V) --> (0.63/5)
Evaluating ... ...
G = 0.126
STEP 3: Convert Result to Output's Unit
0.126 --> No Conversion Required
FINAL ANSWER
0.126 <-- Assumed grit quantity
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Assumed Grit Quantity given Volume of Aerated Grit Chamber Formula

Assumed grit quantity = (Volume/Volumetric Flow Rate)
G = (VT/V)

What is aerated grit chamber ?

An aerated grit removal system removes particles by forcing water that has passed through bar screens into a grit chamber, which has air pumped into it. The air causes a spiral of water to flow through the tank and heavier particles are thrown out of the water's streamline.

How to Calculate Assumed Grit Quantity given Volume of Aerated Grit Chamber?

Assumed Grit Quantity given Volume of Aerated Grit Chamber calculator uses Assumed grit quantity = (Volume/Volumetric Flow Rate) to calculate the Assumed grit quantity, The Assumed Grit Quantity given Volume of Aerated Grit Chamber calculates the assumed value of grit quantity when we know the values of volume of grit and volumetric flow rate. Assumed grit quantity is denoted by G symbol.

How to calculate Assumed Grit Quantity given Volume of Aerated Grit Chamber using this online calculator? To use this online calculator for Assumed Grit Quantity given Volume of Aerated Grit Chamber, enter Volume (VT) & Volumetric Flow Rate (V) and hit the calculate button. Here is how the Assumed Grit Quantity given Volume of Aerated Grit Chamber calculation can be explained with given input values -> 0.126 = (0.63/5).

FAQ

What is Assumed Grit Quantity given Volume of Aerated Grit Chamber?
The Assumed Grit Quantity given Volume of Aerated Grit Chamber calculates the assumed value of grit quantity when we know the values of volume of grit and volumetric flow rate and is represented as G = (VT/V) or Assumed grit quantity = (Volume/Volumetric Flow Rate). Volume is the amount of space that a substance or object occupies or that is enclosed within a container & Volumetric Flow Rate is the volume of fluid which passes per unit time.
How to calculate Assumed Grit Quantity given Volume of Aerated Grit Chamber?
The Assumed Grit Quantity given Volume of Aerated Grit Chamber calculates the assumed value of grit quantity when we know the values of volume of grit and volumetric flow rate is calculated using Assumed grit quantity = (Volume/Volumetric Flow Rate). To calculate Assumed Grit Quantity given Volume of Aerated Grit Chamber, you need Volume (VT) & Volumetric Flow Rate (V). With our tool, you need to enter the respective value for Volume & Volumetric Flow Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!