Chosen Air Supply given Air supply required Solution

STEP 0: Pre-Calculation Summary
Formula Used
Chosen air supply = Air supply required*Length of grit chamber
A = As*L
This formula uses 3 Variables
Variables Used
Chosen air supply - (Measured in Square Meter per Second) - Chosen air supply is the amout of air chosen to supply in grit chamber.
Air supply required - (Measured in Cubic Meter per Second) - Air supply required in the aerated grit chamber.
Length of grit chamber - (Measured in Meter) - Length of grit chamber is the longer dimension of the grit chamber.
STEP 1: Convert Input(s) to Base Unit
Air supply required: 5 Cubic Meter per Second --> 5 Cubic Meter per Second No Conversion Required
Length of grit chamber: 20 Meter --> 20 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = As*L --> 5*20
Evaluating ... ...
A = 100
STEP 3: Convert Result to Output's Unit
100 Square Meter per Second --> No Conversion Required
FINAL ANSWER
100 Square Meter per Second <-- Chosen air supply
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Chosen Air Supply given Air supply required Formula

Chosen air supply = Air supply required*Length of grit chamber
A = As*L

What is grit chamber ?

Grit chambers are long narrow tanks that are designed to slow down the flow so that solids such as sand, coffee grounds, and eggshells will settle out of the water. Grit causes excessive wear and tear on pumps and other plant equipment.

How to Calculate Chosen Air Supply given Air supply required?

Chosen Air Supply given Air supply required calculator uses Chosen air supply = Air supply required*Length of grit chamber to calculate the Chosen air supply, The Chosen Air Supply given Air supply required calculates the value of chosen air supply when we have prior information of air supply required and chamber length . Chosen air supply is denoted by A symbol.

How to calculate Chosen Air Supply given Air supply required using this online calculator? To use this online calculator for Chosen Air Supply given Air supply required, enter Air supply required (As) & Length of grit chamber (L) and hit the calculate button. Here is how the Chosen Air Supply given Air supply required calculation can be explained with given input values -> 100 = 5*20.

FAQ

What is Chosen Air Supply given Air supply required?
The Chosen Air Supply given Air supply required calculates the value of chosen air supply when we have prior information of air supply required and chamber length and is represented as A = As*L or Chosen air supply = Air supply required*Length of grit chamber. Air supply required in the aerated grit chamber & Length of grit chamber is the longer dimension of the grit chamber.
How to calculate Chosen Air Supply given Air supply required?
The Chosen Air Supply given Air supply required calculates the value of chosen air supply when we have prior information of air supply required and chamber length is calculated using Chosen air supply = Air supply required*Length of grit chamber. To calculate Chosen Air Supply given Air supply required, you need Air supply required (As) & Length of grit chamber (L). With our tool, you need to enter the respective value for Air supply required & Length of grit chamber and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!