Coefficient of Permeability given Depth of Water in Two Wells Solution

STEP 0: Pre-Calculation Summary
Formula Used
Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Kw = Q/((2.72*bp*(h2-h1))/(log((r2/r1),10)))
This formula uses 1 Functions, 7 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Coefficient of Permeability - (Measured in Meter per Second) - Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Aquifer Thickness During Pumping - (Measured in Meter) - Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
Depth of Water 2 - (Measured in Meter) - Depth of water 2 means the depth of the water in 2nd well.
Depth of Water 1 - (Measured in Meter) - Depth of water 1 is the depth of water in the 1st considered well.
Radial Distance at Observation Well 2 - (Measured in Meter) - Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Radial Distance at Observation Well 1 - (Measured in Meter) - Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Aquifer Thickness During Pumping: 2.36 Meter --> 2.36 Meter No Conversion Required
Depth of Water 2: 17.8644 Meter --> 17.8644 Meter No Conversion Required
Depth of Water 1: 17.85 Meter --> 17.85 Meter No Conversion Required
Radial Distance at Observation Well 2: 10 Meter --> 10 Meter No Conversion Required
Radial Distance at Observation Well 1: 1.07 Meter --> 1.07 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Kw = Q/((2.72*bp*(h2-h1))/(log((r2/r1),10))) --> 1.01/((2.72*2.36*(17.8644-17.85))/(log((10/1.07),10)))
Evaluating ... ...
Kw = 11.2572012205447
STEP 3: Convert Result to Output's Unit
11.2572012205447 Meter per Second -->1125.72012205447 Centimeter per Second (Check conversion here)
FINAL ANSWER
1125.72012205447 1125.72 Centimeter per Second <-- Coefficient of Permeability
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

5 Coefficient of Permeability Calculators

Coefficient of Permeability given Discharge in Confined Aquifer
Go Coefficient of Permeability in Well Hydraulics = Discharge/((2*pi*Aquifer Thickness During Pumping*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of well),e)))
Coefficient of Permeability given Depth of Water in Two Wells
Go Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Coefficient of Permeability given Confined Aquifer Discharge
Go Coefficient of Permeability in Well Hydraulics = Discharge/((2*pi*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),e)))
Coefficient of Permeability given Discharge in Confined Aquifer with Base 10
Go Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness During Pumping*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),10)))
Coefficient of Permeability given Confined Aquifer Discharge with Base 10
Go Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well in Well Hydraulics)/(log((Radius of Influence/Radius of well),10)))

Coefficient of Permeability given Depth of Water in Two Wells Formula

Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Kw = Q/((2.72*bp*(h2-h1))/(log((r2/r1),10)))

What is Coefficient of Permeability?

The coefficient of permeability of a soil describes how easily a liquid will move through a soil. It is also commonly referred to as the hydraulic conductivity of a soil.

How to Calculate Coefficient of Permeability given Depth of Water in Two Wells?

Coefficient of Permeability given Depth of Water in Two Wells calculator uses Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))) to calculate the Coefficient of Permeability, The Coefficient of Permeability given Depth of Water in Two Wells is defined as the value of the coefficient of permeability when we have prior information on other parameters used. Coefficient of Permeability is denoted by Kw symbol.

How to calculate Coefficient of Permeability given Depth of Water in Two Wells using this online calculator? To use this online calculator for Coefficient of Permeability given Depth of Water in Two Wells, enter Discharge (Q), Aquifer Thickness During Pumping (bp), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) and hit the calculate button. Here is how the Coefficient of Permeability given Depth of Water in Two Wells calculation can be explained with given input values -> 112572 = 1.01/((2.72*2.36*(17.8644-17.85))/(log((10/1.07),10))).

FAQ

What is Coefficient of Permeability given Depth of Water in Two Wells?
The Coefficient of Permeability given Depth of Water in Two Wells is defined as the value of the coefficient of permeability when we have prior information on other parameters used and is represented as Kw = Q/((2.72*bp*(h2-h1))/(log((r2/r1),10))) or Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))). Discharge is the rate of flow of a liquid, Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage, Depth of water 2 means the depth of the water in 2nd well, Depth of water 1 is the depth of water in the 1st considered well, Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used & Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
How to calculate Coefficient of Permeability given Depth of Water in Two Wells?
The Coefficient of Permeability given Depth of Water in Two Wells is defined as the value of the coefficient of permeability when we have prior information on other parameters used is calculated using Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))). To calculate Coefficient of Permeability given Depth of Water in Two Wells, you need Discharge (Q), Aquifer Thickness During Pumping (bp), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1). With our tool, you need to enter the respective value for Discharge, Aquifer Thickness During Pumping, Depth of Water 2, Depth of Water 1, Radial Distance at Observation Well 2 & Radial Distance at Observation Well 1 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!