Condensation Number for Horizontal Cylinder Solution

STEP 0: Pre-Calculation Summary
Formula Used
Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3))
Co = 1.514*((Ref)^(-1/3))
This formula uses 2 Variables
Variables Used
Condensation Number - Condensation Number is defined as the dimensionless number which helps us to resolve equation in terms of film Reynolds number, which is important in determining condensation behavior.
Reynolds Number of Film - Reynolds Number of Film is the ratio of Inertial force to the viscous force.
STEP 1: Convert Input(s) to Base Unit
Reynolds Number of Film: 2000 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Co = 1.514*((Ref)^(-1/3)) --> 1.514*((2000)^(-1/3))
Evaluating ... ...
Co = 0.120166259633993
STEP 3: Convert Result to Output's Unit
0.120166259633993 --> No Conversion Required
FINAL ANSWER
0.120166259633993 <-- Condensation Number
(Calculation completed in 00.000 seconds)

Credits

Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 50+ more calculators!
Verified by Prerana Bakli
National Institute of Technology (NIT), Meghalaya
Prerana Bakli has verified this Calculator and 800+ more calculators!

5 Condensation Number Calculators

Condensation Number
Condensation Number = (Average Heat Transfer Coefficient)* (((Viscosity of Film)^2)/((Thermal Conductivity^3)*(Density of Liquid Film)*(Density of Liquid Film-Density of Vapor)*[g])^(1/3)) Go
Condensation of Superheated Vapors
Heat Transfer = Average Heat Transfer Coefficient*Area of Plate*(Saturation Temperature-Plate Surface Temperature) Go
Condensation Number When Turbulence is Encountered in Film
Condensation Number = 0.0077*((Reynolds Number of Film)^(0.4)) Go
Condensation Number for Horizontal Cylinder
Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3)) Go
Condensation Number for Vertical Plate
Condensation Number = 1.47*((Reynolds Number of Film)^(-1/3)) Go

Condensation Number for Horizontal Cylinder Formula

Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3))
Co = 1.514*((Ref)^(-1/3))

What is Heat Transfer?

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes.

Define Thermal Conductivity & Factors affecting it.

Thermal conductivity is defined as the ability of a substance to conduct heat. Factors Affecting The Thermal Conductivity are: Moisture, Density of material, Pressure, Temperature & Structure of material.

How to Calculate Condensation Number for Horizontal Cylinder?

Condensation Number for Horizontal Cylinder calculator uses Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3)) to calculate the Condensation Number, The Condensation Number for Horizontal Cylinder formula is a function of Reynolds number when A/PL = pi and reynolds number of film is less than 1800. Condensation Number is denoted by Co symbol.

How to calculate Condensation Number for Horizontal Cylinder using this online calculator? To use this online calculator for Condensation Number for Horizontal Cylinder, enter Reynolds Number of Film (Ref) and hit the calculate button. Here is how the Condensation Number for Horizontal Cylinder calculation can be explained with given input values -> 0.120166 = 1.514*((2000)^(-1/3)).

FAQ

What is Condensation Number for Horizontal Cylinder?
The Condensation Number for Horizontal Cylinder formula is a function of Reynolds number when A/PL = pi and reynolds number of film is less than 1800 and is represented as Co = 1.514*((Ref)^(-1/3)) or Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3)). Reynolds Number of Film is the ratio of Inertial force to the viscous force.
How to calculate Condensation Number for Horizontal Cylinder?
The Condensation Number for Horizontal Cylinder formula is a function of Reynolds number when A/PL = pi and reynolds number of film is less than 1800 is calculated using Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3)). To calculate Condensation Number for Horizontal Cylinder, you need Reynolds Number of Film (Ref). With our tool, you need to enter the respective value for Reynolds Number of Film and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Condensation Number?
In this formula, Condensation Number uses Reynolds Number of Film. We can use 4 other way(s) to calculate the same, which is/are as follows -
  • Condensation Number = (Average Heat Transfer Coefficient)* (((Viscosity of Film)^2)/((Thermal Conductivity^3)*(Density of Liquid Film)*(Density of Liquid Film-Density of Vapor)*[g])^(1/3))
  • Condensation Number = ((Constant for Condensation Number)^(4/3))* ((4*sin(Inclination Angle)*(Cross Sectional Area of Flow/Wetted Perimeter)/(Length of Plate))^(1/3))* ((Reynolds Number of Film)^(-1/3))
  • Condensation Number = 1.47*((Reynolds Number of Film)^(-1/3))
  • Condensation Number = 0.0077*((Reynolds Number of Film)^(0.4))
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!