Constant using Volume of Conductor Material(DC Three-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Constant underground dc = Volume Of Conductor/(1.25)
K = V/(1.25)
This formula uses 2 Variables
Variables Used
Constant underground dc - Constant underground dc is used to define all the constant variables in the equation.
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
STEP 1: Convert Input(s) to Base Unit
Volume Of Conductor: 35 Cubic Meter --> 35 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K = V/(1.25) --> 35/(1.25)
Evaluating ... ...
K = 28
STEP 3: Convert Result to Output's Unit
28 --> No Conversion Required
FINAL ANSWER
28 <-- Constant underground dc
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has verified this Calculator and 100+ more calculators!

15 Wire Parameters Calculators

Volume of Conductor Material using Resistance (DC Three-Wire US)
Go Volume Of Conductor = (5*(Power Transmitted^2)*Resistance underground DC*Length of Wire DC*Area of underground dc wire)/(Line Losses*(Maximum Voltage^2))
Length using Volume of Conductor Material(DC Three-Wire US)
Go Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2)))
Length using Area of X-Section (DC Three-Wire US)
Go Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2))
Area of X-Section (DC Three-Wire US)
Go Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2))
Line Losses (DC Three-Wire US)
Go Line Losses = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/((Maximum Voltage^2)*Area of underground dc wire)
Volume of Conductor Material (DC Three-Wire US)
Go Volume Of Conductor = 5*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2))
Line Losses using Volume of Conductor Material(DC Three-Wire US)
Go Line Losses = 5*Resistivity*((Power Transmitted*Length of Wire DC)^2)/(Volume Of Conductor*(Maximum Voltage^2))
Line Losses using Area of X-Section (DC Three-Wire US)
Go Line Losses = 2*(Current underground DC^2)*Resistivity*Length of Wire DC/(Area of underground dc wire)
Length using Line Losses (DC Three-Wire US)
Go Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))
Volume of Conductor Material using Load Current (DC Three-Wire US)
Go Volume Of Conductor = 5*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses
Line Losses using Resistance (DC Three-Wire US)
Go Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2))
Area of X-section using Volume of Conductor Material(DC Three-Wire US)
Go Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC)
Volume of Conductor Material using Area and Length(DC Three-Wire US)
Go Volume Of Conductor = 2.5*Area of underground dc wire*Length of Wire DC
Constant using Volume of Conductor Material(DC Three-Wire US)
Go Constant underground dc = Volume Of Conductor/(1.25)
Volume of Conductor Material using Constant(DC Three-Wire US)
Go Volume Of Conductor = 1.25*Constant underground dc

Constant using Volume of Conductor Material(DC Three-Wire US) Formula

Constant underground dc = Volume Of Conductor/(1.25)
K = V/(1.25)

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Constant using Volume of Conductor Material(DC Three-Wire US)?

Constant using Volume of Conductor Material(DC Three-Wire US) calculator uses Constant underground dc = Volume Of Conductor/(1.25) to calculate the Constant underground dc, The Constant using Volume of Conductor Material(DC Three-Wire US) formula is defined as the total constant of a DC 3-wire underground system. it is represented by K. Constant underground dc is denoted by K symbol.

How to calculate Constant using Volume of Conductor Material(DC Three-Wire US) using this online calculator? To use this online calculator for Constant using Volume of Conductor Material(DC Three-Wire US), enter Volume Of Conductor (V) and hit the calculate button. Here is how the Constant using Volume of Conductor Material(DC Three-Wire US) calculation can be explained with given input values -> 28 = 35/(1.25).

FAQ

What is Constant using Volume of Conductor Material(DC Three-Wire US)?
The Constant using Volume of Conductor Material(DC Three-Wire US) formula is defined as the total constant of a DC 3-wire underground system. it is represented by K and is represented as K = V/(1.25) or Constant underground dc = Volume Of Conductor/(1.25). Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
How to calculate Constant using Volume of Conductor Material(DC Three-Wire US)?
The Constant using Volume of Conductor Material(DC Three-Wire US) formula is defined as the total constant of a DC 3-wire underground system. it is represented by K is calculated using Constant underground dc = Volume Of Conductor/(1.25). To calculate Constant using Volume of Conductor Material(DC Three-Wire US), you need Volume Of Conductor (V). With our tool, you need to enter the respective value for Volume Of Conductor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!