Deoxygenation Constant at given Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
KD(T) = KD(20)*(1.047)^(T-20)
This formula uses 3 Variables
Variables Used
Deoxygenation Constant at Temperature T - (Measured in 1 Per Second) - Deoxygenation constant at temperature T is the BOD rate constant at temperature T.
Deoxygenation Constant at Temperature 20 - (Measured in 1 Per Second) - Deoxygenation constant at temperature 20 is the BOD rate constant at temperature 20°C.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Deoxygenation Constant at Temperature 20: 0.2 1 Per Day --> 2.31481481481481E-06 1 Per Second (Check conversion here)
Temperature: 10 Kelvin --> 10 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KD(T) = KD(20)*(1.047)^(T-20) --> 2.31481481481481E-06*(1.047)^(10-20)
Evaluating ... ...
KD(T) = 1.46234362576591E-06
STEP 3: Convert Result to Output's Unit
1.46234362576591E-06 1 Per Second -->0.126346489266175 1 Per Day (Check conversion here)
FINAL ANSWER
0.126346489266175 0.126346 1 Per Day <-- Deoxygenation Constant at Temperature T
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Deoxygenation Constant Calculators

Deoxygenation Constant given Total Amount of Organic Matter Oxidised
Go Deoxygenation Constant = -(1/Time in days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start))
Deoxygenation Constant given Organic Matter Present at Start of BOD
Go Deoxygenation Constant = -(1/Time in days)*log10(Oxygen Equivalent/Organic Matter at Start)
Deoxygenation Constant at given Temperature
Go Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
Deoxygenation Constant at 20 degree Celsius
Go Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20))
De-oxygenation Constant
Go Deoxygenation Constant = 0.434*Rate Constant in BOD
Deoxygenation Constant
Go Deoxygenation Constant = Rate Constant in BOD/2.3

Deoxygenation Constant at given Temperature Formula

Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
KD(T) = KD(20)*(1.047)^(T-20)

What is BOD?

BOD is a measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria.

How to Calculate Deoxygenation Constant at given Temperature?

Deoxygenation Constant at given Temperature calculator uses Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20) to calculate the Deoxygenation Constant at Temperature T, The Deoxygenation Constant at given Temperature is defined as the BOD rate constant at temperature T at base 10. Its unit is per day. Deoxygenation Constant at Temperature T is denoted by KD(T) symbol.

How to calculate Deoxygenation Constant at given Temperature using this online calculator? To use this online calculator for Deoxygenation Constant at given Temperature, enter Deoxygenation Constant at Temperature 20 (KD(20)) & Temperature (T) and hit the calculate button. Here is how the Deoxygenation Constant at given Temperature calculation can be explained with given input values -> 342040.9 = 2.31481481481481E-06*(1.047)^(10-20).

FAQ

What is Deoxygenation Constant at given Temperature?
The Deoxygenation Constant at given Temperature is defined as the BOD rate constant at temperature T at base 10. Its unit is per day and is represented as KD(T) = KD(20)*(1.047)^(T-20) or Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20). Deoxygenation constant at temperature 20 is the BOD rate constant at temperature 20°C & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Deoxygenation Constant at given Temperature?
The Deoxygenation Constant at given Temperature is defined as the BOD rate constant at temperature T at base 10. Its unit is per day is calculated using Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20). To calculate Deoxygenation Constant at given Temperature, you need Deoxygenation Constant at Temperature 20 (KD(20)) & Temperature (T). With our tool, you need to enter the respective value for Deoxygenation Constant at Temperature 20 & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.