Dynamic Viscosity given Discharge per Unit Channel Width Solution

STEP 0: Pre-Calculation Summary
Formula Used
Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width)
μviscosity = (γf*i*dsection^3)/(3*q)
This formula uses 5 Variables
Variables Used
Dynamic Viscosity - (Measured in Pascal Second) - The Dynamic Viscosity of a fluid is the measure of its resistance to flow when an external force is applied.
Specific Weight of Liquid - (Measured in Newton per Cubic Meter) - Specific Weight of Liquid represents the force exerted by gravity on a unit volume of a fluid.
Slope of bed - The Slope of bed is used to calculate the shear stress at the bed of an open channel containing fluid that is undergoing steady, uniform flow.
Diameter of Section - (Measured in Meter) - Diameter of Section is the diameter of the circular cross-section of the beam.
Discharge per Unit Width - (Measured in Square Meter per Second) - The Discharge per Unit Width is the ratio of total discharge in the channel to the width considered.
STEP 1: Convert Input(s) to Base Unit
Specific Weight of Liquid: 9.81 Kilonewton per Cubic Meter --> 9810 Newton per Cubic Meter (Check conversion here)
Slope of bed: 0.01 --> No Conversion Required
Diameter of Section: 5 Meter --> 5 Meter No Conversion Required
Discharge per Unit Width: 10.02 Square Meter per Second --> 10.02 Square Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
μviscosity = (γf*i*dsection^3)/(3*q) --> (9810*0.01*5^3)/(3*10.02)
Evaluating ... ...
μviscosity = 407.934131736527
STEP 3: Convert Result to Output's Unit
407.934131736527 Pascal Second -->4079.34131736527 Poise (Check conversion here)
FINAL ANSWER
4079.34131736527 4079.341 Poise <-- Dynamic Viscosity
(Calculation completed in 00.004 seconds)

Credits

Created by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has created this Calculator and 1300+ more calculators!
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

18 Laminar Flow of Fluid in an Open Channel Calculators

Slope of Channel given Mean Velocity of Flow
Go Slope of Surface of Constant Pressure = (Dynamic Viscosity*Mean Velocity)/((Diameter of Section*Horizontal Distance-(Horizontal Distance^2)/2)*Specific Weight of Liquid)
Diameter of Section given Mean Velocity of Flow
Go Diameter of Section = ((Horizontal Distance^2+(-Dynamic Viscosity*Mean Velocity*Slope of Surface of Constant Pressure/Specific Weight of Liquid)))/Horizontal Distance
Mean Velocity in flow
Go Mean Velocity = -(Specific Weight of Liquid*Piezometric Gradient*(Diameter of Section*Horizontal Distance-Horizontal Distance^2))/Dynamic Viscosity
Dynamic Viscosity given Mean Velocity of Flow in Section
Go Dynamic Viscosity = (Specific Weight of Liquid*Piezometric Gradient*(Diameter of Section*Horizontal Distance-Horizontal Distance^2))/Mean Velocity
Diameter of Section given Potential Head Drop
Go Diameter of Section = sqrt((3*Dynamic Viscosity*Mean Velocity*Length of Pipe)/(Specific Weight of Liquid*Head Loss due to Friction))
Length of Pipe given Potential Head Drop
Go Length of Pipe = (Head Loss due to Friction*Specific Weight of Liquid*(Diameter of Section^2))/(3*Dynamic Viscosity*Mean Velocity)
Potential Head Drop
Go Head Loss due to Friction = (3*Dynamic Viscosity*Mean Velocity*Length of Pipe)/(Specific Weight of Liquid*Diameter of Section^2)
Diameter of Section given Discharge per Unit Channel Width
Go Diameter of Section = ((3*Dynamic Viscosity*Discharge per Unit Width)/(Slope of bed*Specific Weight of Liquid))^(1/3)
Dynamic Viscosity given Discharge per Unit Channel Width
Go Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width)
Slope of Channel given Discharge per Unit Channel Width
Go Slope of bed = (3*Dynamic Viscosity*Discharge per Unit Width)/(Specific Weight of Liquid*Diameter of Section^3)
Discharge per unit channel width
Go Discharge per Unit Width = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Dynamic Viscosity)
Slope of Channel given Shear Stress
Go Bed Slope = Shear Stress/(Specific Weight of Liquid*(Overall diameter of section-Horizontal Distance))
Diameter of Section given Slope of Channel
Go Diameter of Section = (Shear Stress/(Bed Slope*Specific Weight of Liquid))+Horizontal Distance
Horizontal Distance given Slope of Channel
Go Horizontal Distance = Diameter of Section-(Shear Stress/(Bed Slope*Specific Weight of Liquid))
Shear Stress given Slope of Channel
Go Shear Stress = Specific Weight of Liquid*Bed Slope*(Depth-Horizontal Distance)
Diameter of Section given Bed Shear Stress
Go Diameter of Section = Shear Stress/(Bed Slope*Specific Weight of Liquid)
Bed Slope given Bed Shear Stress
Go Bed Slope = Shear Stress/(Diameter of Section*Specific Weight of Liquid)
Bed Shear Stress
Go Shear Stress = Specific Weight of Liquid*Bed Slope*Diameter of Section

Dynamic Viscosity given Discharge per Unit Channel Width Formula

Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width)
μviscosity = (γf*i*dsection^3)/(3*q)

What is Dynamic Viscosity?

Dynamic viscosity (also known as absolute viscosity) is the measurement of the fluid's internal resistance to flow while kinematic viscosity refers to the ratio of dynamic viscosity to density.

How to Calculate Dynamic Viscosity given Discharge per Unit Channel Width?

Dynamic Viscosity given Discharge per Unit Channel Width calculator uses Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width) to calculate the Dynamic Viscosity, The Dynamic Viscosity given Discharge per Unit Channel Width is defined as resistance offered to relative motion of object in the fluid. Dynamic Viscosity is denoted by μviscosity symbol.

How to calculate Dynamic Viscosity given Discharge per Unit Channel Width using this online calculator? To use this online calculator for Dynamic Viscosity given Discharge per Unit Channel Width, enter Specific Weight of Liquid f), Slope of bed (i), Diameter of Section (dsection) & Discharge per Unit Width (q) and hit the calculate button. Here is how the Dynamic Viscosity given Discharge per Unit Channel Width calculation can be explained with given input values -> 40793.41 = (9810*0.01*5^3)/(3*10.02).

FAQ

What is Dynamic Viscosity given Discharge per Unit Channel Width?
The Dynamic Viscosity given Discharge per Unit Channel Width is defined as resistance offered to relative motion of object in the fluid and is represented as μviscosity = (γf*i*dsection^3)/(3*q) or Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width). Specific Weight of Liquid represents the force exerted by gravity on a unit volume of a fluid, The Slope of bed is used to calculate the shear stress at the bed of an open channel containing fluid that is undergoing steady, uniform flow, Diameter of Section is the diameter of the circular cross-section of the beam & The Discharge per Unit Width is the ratio of total discharge in the channel to the width considered.
How to calculate Dynamic Viscosity given Discharge per Unit Channel Width?
The Dynamic Viscosity given Discharge per Unit Channel Width is defined as resistance offered to relative motion of object in the fluid is calculated using Dynamic Viscosity = (Specific Weight of Liquid*Slope of bed*Diameter of Section^3)/(3*Discharge per Unit Width). To calculate Dynamic Viscosity given Discharge per Unit Channel Width, you need Specific Weight of Liquid f), Slope of bed (i), Diameter of Section (dsection) & Discharge per Unit Width (q). With our tool, you need to enter the respective value for Specific Weight of Liquid, Slope of bed, Diameter of Section & Discharge per Unit Width and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Dynamic Viscosity?
In this formula, Dynamic Viscosity uses Specific Weight of Liquid, Slope of bed, Diameter of Section & Discharge per Unit Width. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Dynamic Viscosity = (Specific Weight of Liquid*Piezometric Gradient*(Diameter of Section*Horizontal Distance-Horizontal Distance^2))/Mean Velocity
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!