Equivalent permeability when transmissivity of aquifer is considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Equivalent Permeability = Transmissivity/Aquifer Thickness
Ke = τ/b
This formula uses 3 Variables
Variables Used
Equivalent Permeability - (Measured in Meter per Second) - Equivalent Permeability is defined when the flow the flow is parallel to stratification.
Transmissivity - (Measured in Square Meter per Second) - Transmissivity describes the ability of the to transmit groundwater throughout its entire saturated thickness.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
STEP 1: Convert Input(s) to Base Unit
Transmissivity: 1.4 Square Meter per Second --> 1.4 Square Meter per Second No Conversion Required
Aquifer Thickness: 15 Meter --> 15 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ke = τ/b --> 1.4/15
Evaluating ... ...
Ke = 0.0933333333333333
STEP 3: Convert Result to Output's Unit
0.0933333333333333 Meter per Second -->9.33333333333333 Centimeter per Second (Check conversion here)
FINAL ANSWER
9.33333333333333 9.333333 Centimeter per Second <-- Equivalent Permeability
(Calculation completed in 00.020 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

21 Coefficient of Permeability Calculators

Hagen Poiseuille flow or mean particle size of porous medium laminar flow through conduit
Go Mean Particle Size of the Porous Medium = sqrt((Coefficient of Permeability (Hagen-Poiseuille)*Dynamic Viscosity of the Fluid)/(Shape Factor*(Unit Weight of Fluid/1000)))
Dynamic viscosity of fluid of laminar flow through conduit or Hagen Poiseuille flow
Go Dynamic Viscosity of the Fluid = (Shape Factor*Mean Particle Size of the Porous Medium^2)*((Unit Weight of Fluid/1000)/Coefficient of Permeability (Hagen-Poiseuille))
Coefficient of permeability from analogy of laminar flow (Hagen Poiseuille flow)
Go Coefficient of Permeability (Hagen-Poiseuille) = Shape Factor*(Mean Particle Size of the Porous Medium^2)*(Unit Weight of Fluid/1000)/Dynamic Viscosity of the Fluid
Coefficient of permeability at any temperature t for standard value of coefficient of permeability
Go Coefficient of Permeability at any Temperature t = (Standard Coefficient of Permeability at 20°C*Kinematic Viscosity at 20° C)/Kinematic Viscosity at t° C
Kinematic Viscosity at 20 degree Celsius for standard value of coefficient of permeability
Go Kinematic Viscosity at 20° C = (Coefficient of Permeability at any Temperature t*Kinematic Viscosity at t° C)/Standard Coefficient of Permeability at 20°C
Kinematic Viscosity for standard value of coefficient of permeability
Go Kinematic Viscosity at t° C = (Standard Coefficient of Permeability at 20°C*Kinematic Viscosity at 20° C)/Coefficient of Permeability at any Temperature t
Standard value of coefficient of permeability
Go Standard Coefficient of Permeability at 20°C = Coefficient of Permeability at any Temperature t*(Kinematic Viscosity at t° C/Kinematic Viscosity at 20° C)
Coefficient of permeability at temperature of permeameter experiment
Go Coefficient of Permeability at the temperature = (Discharge/Cross-Sectional Area)*(1/(Constant Head Difference/Length))
Cross sectional area when coefficient of permeability at permeameter experiment is considered
Go Cross-Sectional Area = Discharge/(Coefficient of Permeability at the temperature*(Constant Head Difference/Length))
Discharge when Coefficient of Permeability at Permeameter Experiment is Considered
Go Discharge = Coefficient of Permeability at the temperature*Cross-Sectional Area*(Constant Head Difference/Length)
Length when Coefficient of Permeability at Permeameter Experiment is Considered
Go Length = (Constant Head Difference*Cross-Sectional Area*Coefficient of Permeability at the temperature)/Discharge
Coefficient of Permeability when Specific or Intrinsic Permeability is Considered
Go Coefficient of Permeability at the temperature = Intrinsic Permeability*((Unit Weight of Fluid/1000)/Dynamic Viscosity of the Fluid)
Specific or Intrinsic Permeability when Coefficient of Permeability is Considered
Go Intrinsic Permeability = (Coefficient of Permeability at the temperature*Dynamic Viscosity of the Fluid)/(Unit Weight of Fluid/1000)
Specific or Intrinsic Permeability when Dynamic Viscosity is Considered
Go Intrinsic Permeability = (Coefficient of Permeability at the temperature*Dynamic Viscosity of the Fluid)/(Unit Weight of Fluid/1000)
Dynamic Viscosity when Specific or Intrinsic Permeability is Considered
Go Dynamic Viscosity of the Fluid = Intrinsic Permeability*((Unit Weight of Fluid/1000)/Coefficient of Permeability at the temperature)
Kinematic Viscosity when Specific or Intrinsic Permeability is Considered
Go Kinematic Viscosity = (Intrinsic Permeability*Acceleration due to Gravity)/Coefficient of Permeability
Equation for Specific or Intrinsic Permeability
Go Intrinsic Permeability = Shape Factor*Mean Particle Size of the Porous Medium^2
Kinematic Viscosity and Dynamic Viscosity Relation
Go Kinematic Viscosity = Dynamic Viscosity of the Fluid/Density of Fluid
Unit weight of fluid
Go Unit Weight of Fluid = Density of Fluid*Acceleration due to Gravity
Coefficient of Permeability when Transmissibility is Considered
Go Coefficient of Permeability = Transmissibility/Aquifer Thickness
Equivalent permeability when transmissivity of aquifer is considered
Go Equivalent Permeability = Transmissivity/Aquifer Thickness

Equivalent permeability when transmissivity of aquifer is considered Formula

Equivalent Permeability = Transmissivity/Aquifer Thickness
Ke = τ/b

What is Aquifer Transmissivity?

Transmissivity describes the ability of the aquifer to transmit groundwater throughout its entire saturated thickness. Transmissivity is measured as the rate at which groundwater can flow through an aquifer section of unit width under a unit hydraulic gradient.

How to Calculate Equivalent permeability when transmissivity of aquifer is considered?

Equivalent permeability when transmissivity of aquifer is considered calculator uses Equivalent Permeability = Transmissivity/Aquifer Thickness to calculate the Equivalent Permeability, The Equivalent permeability when transmissivity of aquifer is considered is defined when the flow is parallel to stratification i,e parallel to layer for horizontal flow, the head h over the same flow path length L will be the same for each layer. Equivalent Permeability is denoted by Ke symbol.

How to calculate Equivalent permeability when transmissivity of aquifer is considered using this online calculator? To use this online calculator for Equivalent permeability when transmissivity of aquifer is considered, enter Transmissivity (τ) & Aquifer Thickness (b) and hit the calculate button. Here is how the Equivalent permeability when transmissivity of aquifer is considered calculation can be explained with given input values -> 933.3333 = 1.4/15.

FAQ

What is Equivalent permeability when transmissivity of aquifer is considered?
The Equivalent permeability when transmissivity of aquifer is considered is defined when the flow is parallel to stratification i,e parallel to layer for horizontal flow, the head h over the same flow path length L will be the same for each layer and is represented as Ke = τ/b or Equivalent Permeability = Transmissivity/Aquifer Thickness. Transmissivity describes the ability of the to transmit groundwater throughout its entire saturated thickness & Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
How to calculate Equivalent permeability when transmissivity of aquifer is considered?
The Equivalent permeability when transmissivity of aquifer is considered is defined when the flow is parallel to stratification i,e parallel to layer for horizontal flow, the head h over the same flow path length L will be the same for each layer is calculated using Equivalent Permeability = Transmissivity/Aquifer Thickness. To calculate Equivalent permeability when transmissivity of aquifer is considered, you need Transmissivity (τ) & Aquifer Thickness (b). With our tool, you need to enter the respective value for Transmissivity & Aquifer Thickness and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!