Impedance-3 using Reflected Coefficient of Current (Line PL) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Z3 = (2/Z1*(-ρv+1))-(1/Z1)-(1/Z2)
This formula uses 4 Variables
Variables Used
Impedance of Tertiary Winding - (Measured in Ohm) - Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system.
Impedance of Primary Winding - (Measured in Ohm) - The Impedance of Primary Winding is the total of primary Resistance and Reactance.
Reflection Coefficient of Voltage - Reflection Coefficient Of Voltage is defined as the ratio of the reflected voltage to the incident voltage of the Transmission line during any transient condition.
Impedance of Secondary Winding - (Measured in Ohm) - The Impedance of Secondary Winding is the impedance that is in Secondary winding.
STEP 1: Convert Input(s) to Base Unit
Impedance of Primary Winding: 18 Ohm --> 18 Ohm No Conversion Required
Reflection Coefficient of Voltage: 5 --> No Conversion Required
Impedance of Secondary Winding: 16 Ohm --> 16 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z3 = (2/Z1*(-ρv+1))-(1/Z1)-(1/Z2) --> (2/18*(-5+1))-(1/18)-(1/16)
Evaluating ... ...
Z3 = -0.5625
STEP 3: Convert Result to Output's Unit
-0.5625 Ohm --> No Conversion Required
FINAL ANSWER
-0.5625 Ohm <-- Impedance of Tertiary Winding
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

20 Impedance-1,2 & 3 Calculators

Impedance-1 using Reflected Coefficient of Current (Line PL)
Go Impedance of Primary Winding = (-1)*(1-Reflection Coefficient of Voltage)/((Reflection Coefficient of Voltage+1)*((1/Impedance of Secondary Winding)+(1/Impedance of Tertiary Winding)))
Impedance-1 using Transmitted Voltage (Line PL)
Go Impedance of Primary Winding = (Incident Voltage-Reflected Voltage)*(Impedance of Secondary Winding+Impedance of Tertiary Winding)/Transmitted Voltage
Impedance-2 using Reflected Coefficient of Current (Line PL)
Go Impedance of Secondary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Tertiary Winding)
Impedance-3 using Reflected Coefficient of Current (Line PL)
Go Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Impedance-2 using Transmitted Coefficient of Voltage (Line PL)
Go Impedance of Secondary Winding = (2/(Impedance of Primary Winding*Transmission Coefficient of Voltage))-(1/Impedance of Primary Winding)-(1/Impedance of Tertiary Winding)
Impedance-3 using Transmitted Coefficient of Voltage (Line PL)
Go Impedance of Tertiary Winding = (2/(Impedance of Primary Winding*Transmission Coefficient of Voltage))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Impedance-3 using Reflected Coefficient of Voltage (Line PL)
Go Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Impedance-2 using Reflected Coefficient of Voltage (Line PL)
Go Impedance of Secondary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Tertiary Winding)
Impedance-2 using Transmitted Coefficient of Current-2 (Line PL)
Go Impedance of Secondary Winding = Transmitted Voltage*Impedance of Primary Winding/(Transmission Coefficient of Current*Incident Voltage)
Impedance-1 using Transmitted Coefficient of Current-2 (Line PL)
Go Impedance of Primary Winding = Transmission Coefficient of Current*Incident Voltage*Impedance of Secondary Winding/(Transmitted Voltage)
Impedance-3 using Transmitted Coefficient of Current-3 (Line PL)
Go Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current)
Impedance-1 for Transmitted Coefficient of Current-2 (Line PL)
Go Impedance of Primary Winding = Transmission Coefficient of Current*Impedance of Secondary Winding/Transmission Coefficient of Voltage
Impedance-2 for Transmitted Coefficient of Current-2 (Line PL)
Go Impedance of Secondary Winding = Impedance of Primary Winding*Transmission Coefficient of Voltage/Transmission Coefficient of Current
Impedance-1 using Transmitted Coefficient of Current-3 (Line PL)
Go Impedance of Primary Winding = Transmission Coefficient of Current*Impedance of Tertiary Winding/Transmission Coefficient of Voltage
Impedance-1 for Transmitted Coefficient of Current-3 (Line PL)
Go Impedance of Primary Winding = Transmission Coefficient of Current*Impedance of Tertiary Winding/Transmission Coefficient of Voltage
Impedance-3 for Transmitted Coefficient of Current-3 (Line PL)
Go Impedance of Tertiary Winding = Transmission Coefficient of Voltage*Impedance of Primary Winding/Transmission Coefficient of Current
Impedance-2 using Transmitted Current-2 (Line PL)
Go Impedance of Secondary Winding = Transmitted Voltage/Transmitted Current
Impedance-2 using Transmitted Voltage (Line PL)
Go Impedance of Secondary Winding = Transmitted Voltage/Transmitted Current
Impedance-3 using Transmitted Voltage (Line PL)
Go Impedance of Tertiary Winding = Transmitted Voltage/Transmitted Current
Impedance-1 using Incident Current and Voltage (Line PL)
Go Impedance of Primary Winding = Incident Voltage/Incident Current

Impedance-3 using Reflected Coefficient of Current (Line PL) Formula

Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Z3 = (2/Z1*(-ρv+1))-(1/Z1)-(1/Z2)

What is reflected Coefficient Of Current?

The reflected Coefficient Of Current is defined as the ratio of the Reflected Current to the incident Current of the Transmission line.

How to Calculate Impedance-3 using Reflected Coefficient of Current (Line PL)?

Impedance-3 using Reflected Coefficient of Current (Line PL) calculator uses Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding) to calculate the Impedance of Tertiary Winding, The Impedance-3 using Reflected Coefficient of Current (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance-3 is measured in ohms. Impedance of Tertiary Winding is denoted by Z3 symbol.

How to calculate Impedance-3 using Reflected Coefficient of Current (Line PL) using this online calculator? To use this online calculator for Impedance-3 using Reflected Coefficient of Current (Line PL), enter Impedance of Primary Winding (Z1), Reflection Coefficient of Voltage v) & Impedance of Secondary Winding (Z2) and hit the calculate button. Here is how the Impedance-3 using Reflected Coefficient of Current (Line PL) calculation can be explained with given input values -> -0.5625 = (2/18*(-5+1))-(1/18)-(1/16).

FAQ

What is Impedance-3 using Reflected Coefficient of Current (Line PL)?
The Impedance-3 using Reflected Coefficient of Current (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance-3 is measured in ohms and is represented as Z3 = (2/Z1*(-ρv+1))-(1/Z1)-(1/Z2) or Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding). The Impedance of Primary Winding is the total of primary Resistance and Reactance, Reflection Coefficient Of Voltage is defined as the ratio of the reflected voltage to the incident voltage of the Transmission line during any transient condition & The Impedance of Secondary Winding is the impedance that is in Secondary winding.
How to calculate Impedance-3 using Reflected Coefficient of Current (Line PL)?
The Impedance-3 using Reflected Coefficient of Current (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance-3 is measured in ohms is calculated using Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(-Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding). To calculate Impedance-3 using Reflected Coefficient of Current (Line PL), you need Impedance of Primary Winding (Z1), Reflection Coefficient of Voltage v) & Impedance of Secondary Winding (Z2). With our tool, you need to enter the respective value for Impedance of Primary Winding, Reflection Coefficient of Voltage & Impedance of Secondary Winding and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Impedance of Tertiary Winding?
In this formula, Impedance of Tertiary Winding uses Impedance of Primary Winding, Reflection Coefficient of Voltage & Impedance of Secondary Winding. We can use 5 other way(s) to calculate the same, which is/are as follows -
  • Impedance of Tertiary Winding = Transmitted Voltage/Transmitted Current
  • Impedance of Tertiary Winding = (2/(Impedance of Primary Winding*Transmission Coefficient of Voltage))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
  • Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current)
  • Impedance of Tertiary Winding = Transmission Coefficient of Voltage*Impedance of Primary Winding/Transmission Coefficient of Current
  • Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!