Initial Reactant Concentration for Zero Order Reaction for Mixed Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR
Co-MFR = (k0-MFR*𝛕MFR)/XMFR
This formula uses 4 Variables
Variables Used
Initial Reactant Concentration in MFR - (Measured in Mole per Cubic Meter) - The Initial Reactant Concentration in MFR refers to the amount of reactant present in the solvent before the considered process.
Rate Constant for Zero Order Reaction in MFR - (Measured in Mole per Cubic Meter Second) - Rate Constant for Zero Order Reaction in MFR is equal to the rate of the reaction the rate of reaction is proportional to zero power of the concentration of the reactant.
Space Time in MFR - (Measured in Second) - Space Time in MFR is the time necessary to process volume of reactor fluid at the entrance conditions.
Reactant Conversion in MFR - Reactant Conversion in MFR gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
STEP 1: Convert Input(s) to Base Unit
Rate Constant for Zero Order Reaction in MFR: 1021 Mole per Cubic Meter Second --> 1021 Mole per Cubic Meter Second No Conversion Required
Space Time in MFR: 0.0612 Second --> 0.0612 Second No Conversion Required
Reactant Conversion in MFR: 0.702 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Co-MFR = (k0-MFR*𝛕MFR)/XMFR --> (1021*0.0612)/0.702
Evaluating ... ...
Co-MFR = 89.0102564102564
STEP 3: Convert Result to Output's Unit
89.0102564102564 Mole per Cubic Meter --> No Conversion Required
FINAL ANSWER
89.0102564102564 89.01026 Mole per Cubic Meter <-- Initial Reactant Concentration in MFR
(Calculation completed in 00.004 seconds)

Credits

Created by akhilesh
K. K. Wagh Institute of Engineering Education and Research (K.K.W.I.E.E.R.), Nashik
akhilesh has created this Calculator and 200+ more calculators!
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

9 Mixed Flow Calculators

Initial Reactant Concentration for Second Order Reaction for Mixed Flow
Go Initial Reactant Conc for 2nd Order Mixed Flow = (1/Space Time in MFR*Rate Constant for Second Order Reaction in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Space Time for Second Order Reaction using Rate Constant for Mixed Flow
Go Space Time for Mixed Flow = (1/Rate Constant for Second Order Reaction in MFR*Initial Reactant Concentration in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Rate Constant for Second Order Reaction for Mixed Flow
Go Rate Constant for 2ndOrder Reaction for Mixed Flow = (1/Space Time in MFR*Initial Reactant Concentration in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Space Time for First Order Reaction using Rate Constant for Mixed Flow
Go Space Time in MFR = (1/Rate Constant for First Order Reaction in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR)))/(1-Reactant Conversion in MFR))
Rate Constant for First Order Reaction for Mixed Flow
Go Rate Constant for First Order Reaction in MFR = (1/Space Time in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR)))/(1-Reactant Conversion in MFR))
Initial Reactant Concentration for Zero Order Reaction for Mixed Flow
Go Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR
Space Time for Zero Order Reaction using Rate Constant for Mixed Flow
Go Space Time in MFR = (Reactant Conversion in MFR*Initial Reactant Concentration in MFR)/Rate Constant for Zero Order Reaction in MFR
Reactant Conversion for Zero Order Reaction for Mixed Flow
Go Reactant Conversion in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Initial Reactant Concentration in MFR
Rate Constant for Zero Order Reaction for Mixed Flow
Go Rate Constant for Zero Order Reaction in MFR = (Reactant Conversion in MFR*Initial Reactant Concentration in MFR)/Space Time in MFR

17 Reactor Performance Equations for Variable Volume Reactions Calculators

Initial Reactant Concentration for Second Order Reaction for Plug Flow
Go Initial Reactant Conc for 2nd Order Plug Flow = (1/(Space Time in PFR*Rate Constant for Second Order Reaction))*(2*Fractional Volume Change in PFR*(1+Fractional Volume Change in PFR)*ln(1-Reactant Conversion in PFR)+Fractional Volume Change in PFR^2*Reactant Conversion in PFR+((Fractional Volume Change in PFR+1)^2*Reactant Conversion in PFR/(1-Reactant Conversion in PFR)))
Rate Constant for Second Order Reaction for Plug Flow
Go Rate Constant for 2nd Order Reaction for Plug Flow = (1/(Space Time*Initial Reactant Concentration))*(2*Fractional Volume Change*(1+Fractional Volume Change)*ln(1-Reactant Conversion)+Fractional Volume Change^2*Reactant Conversion+((Fractional Volume Change+1)^2*Reactant Conversion/(1-Reactant Conversion)))
Initial Reactant Concentration for Second Order Reaction for Mixed Flow
Go Initial Reactant Conc for 2nd Order Mixed Flow = (1/Space Time in MFR*Rate Constant for Second Order Reaction in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Space Time for Second Order Reaction using Rate Constant for Mixed Flow
Go Space Time for Mixed Flow = (1/Rate Constant for Second Order Reaction in MFR*Initial Reactant Concentration in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Rate Constant for Second Order Reaction for Mixed Flow
Go Rate Constant for 2ndOrder Reaction for Mixed Flow = (1/Space Time in MFR*Initial Reactant Concentration in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR))^2)/(1-Reactant Conversion in MFR)^2)
Space Time for First Order Reaction using Rate Constant for Plug Flow
Go Space Time in PFR = (1/Rate Constant for First Order in Plug Flow)*((1+Fractional Volume Change in PFR)*ln(1/(1-Reactant Conversion in PFR))-(Fractional Volume Change in PFR*Reactant Conversion in PFR))
Rate Constant for First Order Reaction for Plug Flow
Go Rate Constant for First Order in Plug Flow = (1/Space Time in PFR)*((1+Fractional Volume Change in PFR)*ln(1/(1-Reactant Conversion in PFR))-(Fractional Volume Change in PFR*Reactant Conversion in PFR))
Space Time for First Order Reaction using Rate Constant for Mixed Flow
Go Space Time in MFR = (1/Rate Constant for First Order Reaction in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR)))/(1-Reactant Conversion in MFR))
Rate Constant for First Order Reaction for Mixed Flow
Go Rate Constant for First Order Reaction in MFR = (1/Space Time in MFR)*((Reactant Conversion in MFR*(1+(Fractional Volume Change in Reactor*Reactant Conversion in MFR)))/(1-Reactant Conversion in MFR))
Initial Reactant Concentration for Zero Order Reaction for Mixed Flow
Go Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR
Space Time for Zero Order Reaction using Rate Constant for Mixed Flow
Go Space Time in MFR = (Reactant Conversion in MFR*Initial Reactant Concentration in MFR)/Rate Constant for Zero Order Reaction in MFR
Reactant Conversion for Zero Order Reaction for Mixed Flow
Go Reactant Conversion in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Initial Reactant Concentration in MFR
Rate Constant for Zero Order Reaction for Mixed Flow
Go Rate Constant for Zero Order Reaction in MFR = (Reactant Conversion in MFR*Initial Reactant Concentration in MFR)/Space Time in MFR
Initial Reactant Concentration for Zero Order Reaction for Plug Flow
Go Initial Reactant Concentration in PFR = (Rate Constant for Zero Order Reaction*Space Time in PFR)/Reactant Conversion in PFR
Space Time for Zero Order Reaction using Rate Constant for Plug Flow
Go Space Time in PFR = (Reactant Conversion in PFR*Initial Reactant Concentration in PFR)/Rate Constant for Zero Order Reaction
Reactant Conversion for Zero Order Reaction for Plug Flow
Go Reactant Conversion in PFR = (Rate Constant for Zero Order Reaction*Space Time in PFR)/Initial Reactant Concentration in PFR
Rate Constant for Zero Order Reaction for Plug Flow
Go Rate Constant for Zero Order Reaction = (Reactant Conversion in PFR*Initial Reactant Concentration in PFR)/Space Time in PFR

Initial Reactant Concentration for Zero Order Reaction for Mixed Flow Formula

Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR
Co-MFR = (k0-MFR*𝛕MFR)/XMFR

What is continuous stirred-tank reactor?

The continuous stirred-tank reactor (CSTR), also known as vat- or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using a continuous agitated-tank reactor to reach a specified output. The mathematical model works for all fluids: liquids, gases, and slurries.

How to Calculate Initial Reactant Concentration for Zero Order Reaction for Mixed Flow?

Initial Reactant Concentration for Zero Order Reaction for Mixed Flow calculator uses Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR to calculate the Initial Reactant Concentration in MFR, The Initial Reactant Concentration for Zero Order Reaction for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction where there is considerable fractional volume change. Initial Reactant Concentration in MFR is denoted by Co-MFR symbol.

How to calculate Initial Reactant Concentration for Zero Order Reaction for Mixed Flow using this online calculator? To use this online calculator for Initial Reactant Concentration for Zero Order Reaction for Mixed Flow, enter Rate Constant for Zero Order Reaction in MFR (k0-MFR), Space Time in MFR (𝛕MFR) & Reactant Conversion in MFR (XMFR) and hit the calculate button. Here is how the Initial Reactant Concentration for Zero Order Reaction for Mixed Flow calculation can be explained with given input values -> 89.26457 = (1021*0.0612)/0.702.

FAQ

What is Initial Reactant Concentration for Zero Order Reaction for Mixed Flow?
The Initial Reactant Concentration for Zero Order Reaction for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction where there is considerable fractional volume change and is represented as Co-MFR = (k0-MFR*𝛕MFR)/XMFR or Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR. Rate Constant for Zero Order Reaction in MFR is equal to the rate of the reaction the rate of reaction is proportional to zero power of the concentration of the reactant, Space Time in MFR is the time necessary to process volume of reactor fluid at the entrance conditions & Reactant Conversion in MFR gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
How to calculate Initial Reactant Concentration for Zero Order Reaction for Mixed Flow?
The Initial Reactant Concentration for Zero Order Reaction for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction where there is considerable fractional volume change is calculated using Initial Reactant Concentration in MFR = (Rate Constant for Zero Order Reaction in MFR*Space Time in MFR)/Reactant Conversion in MFR. To calculate Initial Reactant Concentration for Zero Order Reaction for Mixed Flow, you need Rate Constant for Zero Order Reaction in MFR (k0-MFR), Space Time in MFR (𝛕MFR) & Reactant Conversion in MFR (XMFR). With our tool, you need to enter the respective value for Rate Constant for Zero Order Reaction in MFR, Space Time in MFR & Reactant Conversion in MFR and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!