Length of Tank given Settling Velocity of Particular Sized Particle Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length = (70*Discharge)/(100*Width*Settling Velocity)
L = (70*Q)/(100*w*vs)
This formula uses 4 Variables
Variables Used
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Width - (Measured in Meter) - Width is the measurement or extent of something from side to side.
Settling Velocity - (Measured in Meter per Second) - Settling velocity is defined as the terminal velocity of a particle in still fluid.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Width: 2.29 Meter --> 2.29 Meter No Conversion Required
Settling Velocity: 1.5 Meter per Second --> 1.5 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = (70*Q)/(100*w*vs) --> (70*1.01)/(100*2.29*1.5)
Evaluating ... ...
L = 0.205822416302766
STEP 3: Convert Result to Output's Unit
0.205822416302766 Meter --> No Conversion Required
FINAL ANSWER
0.205822416302766 0.205822 Meter <-- Length
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

5 Length of Tank Calculators

Length of Tank given Detention Time
Go Length = (Detention time*Discharge)/(Width*Depth)
Length of Tank given Settling Velocity of Particular Sized Particle
Go Length = (70*Discharge)/(100*Width*Settling Velocity)
Length of Tank given Flow Velocity
Go Length = (Flow Velocity*Depth)/Settling Velocity
Length of Tank given Settling Velocity
Go Length = (Discharge/(Settling Velocity*Width))
Length of Tank given Overflow Rate
Go Length = (Discharge/(Overflow Rate*Width))

Length of Tank given Settling Velocity of Particular Sized Particle Formula

Length = (70*Discharge)/(100*Width*Settling Velocity)
L = (70*Q)/(100*w*vs)

What is settling velocity ?

The settling velocity (also referred to as the “sedimentation velocity”) is defined as the terminal velocity of a particle in still fluid.

How to Calculate Length of Tank given Settling Velocity of Particular Sized Particle?

Length of Tank given Settling Velocity of Particular Sized Particle calculator uses Length = (70*Discharge)/(100*Width*Settling Velocity) to calculate the Length, Length of Tank given Settling Velocity of Particular Sized Particle calculates length of sedimentation tank when we have prior information of other parameters used. Length is denoted by L symbol.

How to calculate Length of Tank given Settling Velocity of Particular Sized Particle using this online calculator? To use this online calculator for Length of Tank given Settling Velocity of Particular Sized Particle, enter Discharge (Q), Width (w) & Settling Velocity (vs) and hit the calculate button. Here is how the Length of Tank given Settling Velocity of Particular Sized Particle calculation can be explained with given input values -> 0.203785 = (70*discharge)/(100*2.29*1.5).

FAQ

What is Length of Tank given Settling Velocity of Particular Sized Particle?
Length of Tank given Settling Velocity of Particular Sized Particle calculates length of sedimentation tank when we have prior information of other parameters used and is represented as L = (70*Q)/(100*w*vs) or Length = (70*Discharge)/(100*Width*Settling Velocity). Discharge is the rate of flow of a liquid, Width is the measurement or extent of something from side to side & Settling velocity is defined as the terminal velocity of a particle in still fluid.
How to calculate Length of Tank given Settling Velocity of Particular Sized Particle?
Length of Tank given Settling Velocity of Particular Sized Particle calculates length of sedimentation tank when we have prior information of other parameters used is calculated using Length = (70*Discharge)/(100*Width*Settling Velocity). To calculate Length of Tank given Settling Velocity of Particular Sized Particle, you need Discharge (Q), Width (w) & Settling Velocity (vs). With our tool, you need to enter the respective value for Discharge, Width & Settling Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length?
In this formula, Length uses Discharge, Width & Settling Velocity. We can use 4 other way(s) to calculate the same, which is/are as follows -
  • Length = (Flow Velocity*Depth)/Settling Velocity
  • Length = (Discharge/(Settling Velocity*Width))
  • Length = (Discharge/(Overflow Rate*Width))
  • Length = (Detention time*Discharge)/(Width*Depth)