Length using Line Losses (DC Two-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))
l = A*Pline/(2*ρ*(C1^2))
This formula uses 5 Variables
Variables Used
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the measurement or extent of something from end to end.
Area of underground dc wire - (Measured in Square Meter) - The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Line Losses - (Measured in Watt) - Line Losses is defined as the losses that are produced in the line.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Current underground DC - (Measured in Ampere) - Current underground DC is defined as the current flowing through the overhead ac supply wire.
STEP 1: Convert Input(s) to Base Unit
Area of underground dc wire: 0.32 Square Meter --> 0.32 Square Meter No Conversion Required
Line Losses: 0.6 Watt --> 0.6 Watt No Conversion Required
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Current underground DC: 3 Ampere --> 3 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
l = A*Pline/(2*ρ*(C1^2)) --> 0.32*0.6/(2*1.7E-05*(3^2))
Evaluating ... ...
l = 627.450980392157
STEP 3: Convert Result to Output's Unit
627.450980392157 Meter --> No Conversion Required
FINAL ANSWER
627.450980392157 627.451 Meter <-- Length of Wire DC
(Calculation completed in 00.019 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

10+ Wire Parameters Calculators

Volume of Conductor Material using Resistance (DC Two-Wire US)
Go Volume Of Conductor = (4*(Power Transmitted^2)*Resistance underground DC*Area of underground dc wire*Length of Wire DC)/(Line Losses*(Maximum Voltage^2))
Length using Area of X-Section (DC Two-Wire US)
Go Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2))
Area of X-Section (DC Two-Wire US)
Go Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2))
Line Losses (DC Two-Wire US)
Go Line Losses = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/((Maximum Voltage^2)*Area of underground dc wire)
Volume of Conductor Material (DC Two-Wire US)
Go Volume Of Conductor = 4*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2))
Line Losses using Area of X-Section(DC Two-Wire US)
Go Line Losses = 2*(Current underground DC^2)*Resistivity*Length of Wire DC/(Area of underground dc wire)
Length using Line Losses (DC Two-Wire US)
Go Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))
Volume of Conductor Material using Load Current (DC Two-Wire US)
Go Volume Of Conductor = 4*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses
Line Losses using Resistance (DC Two-Wire US)
Go Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2))
Volume of Conductor Material using Area and Length(DC Two-Wire US)
Go Volume Of Conductor = Area of underground dc wire*Length of Wire DC*2

Length using Line Losses (DC Two-Wire US) Formula

Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))
l = A*Pline/(2*ρ*(C1^2))

What is the volume of conductor material in DC Two-Wire underground system?

The volume of conductor material required in this system is 1 times that of a 2-wire d.c.system with the one conductor earthed.

How to Calculate Length using Line Losses (DC Two-Wire US)?

Length using Line Losses (DC Two-Wire US) calculator uses Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2)) to calculate the Length of Wire DC, The Length using Line Losses (DC Two-Wire US) formula is defined as the total length of the wire that used in the DC Two-Wire system. Length of Wire DC is denoted by l symbol.

How to calculate Length using Line Losses (DC Two-Wire US) using this online calculator? To use this online calculator for Length using Line Losses (DC Two-Wire US), enter Area of underground dc wire (A), Line Losses (Pline), Resistivity (ρ) & Current underground DC (C1) and hit the calculate button. Here is how the Length using Line Losses (DC Two-Wire US) calculation can be explained with given input values -> 627.451 = 0.32*0.6/(2*1.7E-05*(3^2)).

FAQ

What is Length using Line Losses (DC Two-Wire US)?
The Length using Line Losses (DC Two-Wire US) formula is defined as the total length of the wire that used in the DC Two-Wire system and is represented as l = A*Pline/(2*ρ*(C1^2)) or Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2)). The Area of underground dc wire is the amount of two-dimensional space taken up by an object, Line Losses is defined as the losses that are produced in the line, Resistivity is the measure of how strongly a material opposes the flow of current through them & Current underground DC is defined as the current flowing through the overhead ac supply wire.
How to calculate Length using Line Losses (DC Two-Wire US)?
The Length using Line Losses (DC Two-Wire US) formula is defined as the total length of the wire that used in the DC Two-Wire system is calculated using Length of Wire DC = Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2)). To calculate Length using Line Losses (DC Two-Wire US), you need Area of underground dc wire (A), Line Losses (Pline), Resistivity (ρ) & Current underground DC (C1). With our tool, you need to enter the respective value for Area of underground dc wire, Line Losses, Resistivity & Current underground DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length of Wire DC?
In this formula, Length of Wire DC uses Area of underground dc wire, Line Losses, Resistivity & Current underground DC. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!