Maximum Power using Constant(DC 3-Wire) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses))
Vm = sqrt(((P^2)*ρ*(L^2))/(K*Ploss))
This formula uses 1 Functions, 6 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Maximum Voltage Overhead DC - (Measured in Volt) - Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the total length of the wire from one end to other end.
Constant Overhead DC - Constant Overhead DC is defined as the constant of line of a Overhead supply system.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 920 Watt --> 920 Watt No Conversion Required
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Wire DC: 12.7 Meter --> 12.7 Meter No Conversion Required
Constant Overhead DC: 7 --> No Conversion Required
Line Losses: 0.74 Watt --> 0.74 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vm = sqrt(((P^2)*ρ*(L^2))/(K*Ploss)) --> sqrt(((920^2)*1.7E-05*(12.7^2))/(7*0.74))
Evaluating ... ...
Vm = 21.1666012869003
STEP 3: Convert Result to Output's Unit
21.1666012869003 Volt --> No Conversion Required
FINAL ANSWER
21.1666012869003 21.1666 Volt <-- Maximum Voltage Overhead DC
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has verified this Calculator and 100+ more calculators!

8 Current & Voltage Calculators

Maximum Voltage using Volume of Conductor Material (DC 3-Wire)
Go Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*(0.3125)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*Line Losses))
Maximum Power using Constant(DC 3-Wire)
Go Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses))
Maximum Voltage using Area of X-Section(DC 3-Wire)
Go Maximum Voltage Overhead DC = sqrt((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*Line Losses))
Maximum Voltage using Line Losses(DC 3-Wire)
Go Maximum Voltage Overhead DC = Power Transmitted*sqrt(Resistivity*Length of Wire DC/(Line Losses*2*Area of Overhead DC Wire))
Load Current using Area of X-Section(DC 3-Wire)
Go Current Overhead DC = sqrt(Area of Overhead DC Wire*Line Losses/(Resistivity*Length of Wire DC))
Load Current using Line Losses(DC 3-Wire)
Go Current Overhead DC = sqrt(Line Losses/(2*Resistance Overhead DC))
Load Current(DC 3-Wire)
Go Current Overhead DC = Power Transmitted per Phase/(2*Maximum Voltage Overhead DC)
Maximum Power using Load Current(DC 3-Wire)
Go Maximum Voltage Overhead DC = Power Transmitted/(2*Current Overhead DC)

Maximum Power using Constant(DC 3-Wire) Formula

Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses))
Vm = sqrt(((P^2)*ρ*(L^2))/(K*Ploss))

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Maximum Power using Constant(DC 3-Wire)?

Maximum Power using Constant(DC 3-Wire) calculator uses Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses)) to calculate the Maximum Voltage Overhead DC, The Maximum Power using Constant(DC 3-wire) formula is defined as the absolute maximum rated supply voltage is the maximum voltage that can be supplied between the positive supply (VCC) and negative supply (VEE) pins without causing characteristics degradation or damage to the internal circuit. Maximum Voltage Overhead DC is denoted by Vm symbol.

How to calculate Maximum Power using Constant(DC 3-Wire) using this online calculator? To use this online calculator for Maximum Power using Constant(DC 3-Wire), enter Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Constant Overhead DC (K) & Line Losses (Ploss) and hit the calculate button. Here is how the Maximum Power using Constant(DC 3-Wire) calculation can be explained with given input values -> 21.1666 = sqrt(((920^2)*1.7E-05*(12.7^2))/(7*0.74)).

FAQ

What is Maximum Power using Constant(DC 3-Wire)?
The Maximum Power using Constant(DC 3-wire) formula is defined as the absolute maximum rated supply voltage is the maximum voltage that can be supplied between the positive supply (VCC) and negative supply (VEE) pins without causing characteristics degradation or damage to the internal circuit and is represented as Vm = sqrt(((P^2)*ρ*(L^2))/(K*Ploss)) or Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses)). Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end, Resistivity is the measure of how strongly a material opposes the flow of current through them, Length of Wire DC is the total length of the wire from one end to other end, Constant Overhead DC is defined as the constant of line of a Overhead supply system & Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
How to calculate Maximum Power using Constant(DC 3-Wire)?
The Maximum Power using Constant(DC 3-wire) formula is defined as the absolute maximum rated supply voltage is the maximum voltage that can be supplied between the positive supply (VCC) and negative supply (VEE) pins without causing characteristics degradation or damage to the internal circuit is calculated using Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*Line Losses)). To calculate Maximum Power using Constant(DC 3-Wire), you need Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Constant Overhead DC (K) & Line Losses (Ploss). With our tool, you need to enter the respective value for Power Transmitted, Resistivity, Length of Wire DC, Constant Overhead DC & Line Losses and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Voltage Overhead DC?
In this formula, Maximum Voltage Overhead DC uses Power Transmitted, Resistivity, Length of Wire DC, Constant Overhead DC & Line Losses. We can use 4 other way(s) to calculate the same, which is/are as follows -
  • Maximum Voltage Overhead DC = Power Transmitted/(2*Current Overhead DC)
  • Maximum Voltage Overhead DC = Power Transmitted*sqrt(Resistivity*Length of Wire DC/(Line Losses*2*Area of Overhead DC Wire))
  • Maximum Voltage Overhead DC = sqrt(((Power Transmitted^2)*(0.3125)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*Line Losses))
  • Maximum Voltage Overhead DC = sqrt((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*Line Losses))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!