Microbial Mass in Aeration System Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Microbial Mass = MLSS*Volume of Tank
Mt = X*V
This formula uses 3 Variables
Variables Used
Total Microbial Mass - (Measured in Kilogram) - Total microbial mass in the system in grams.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics).
Volume of Tank - (Measured in Cubic Meter) - Volume of tank is defined as the capacity of flocculation and mixing tank.
STEP 1: Convert Input(s) to Base Unit
MLSS: 1200 Milligram per Liter --> 1.2 Kilogram per Cubic Meter (Check conversion here)
Volume of Tank: 9 Cubic Meter --> 9 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Mt = X*V --> 1.2*9
Evaluating ... ...
Mt = 10.8
STEP 3: Convert Result to Output's Unit
10.8 Kilogram -->10800 Gram (Check conversion here)
FINAL ANSWER
10800 Gram <-- Total Microbial Mass
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

20 Food to Microorganism Ratio or F/M Ratio Calculators

Microbial Mass in Aeration System given MLSS
Go Total Microbial Mass = Daily bod/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS))
BOD Load Applied given MLSS
Go Daily bod = Total Microbial Mass*((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS))
MLSS given BOD Load Applied to Aeration System
Go MLSS = (Total Microbial Mass*Sewage Flow*Influent BOD)/(Volume of Tank*Daily bod)
Volume of Tank given MLSS
Go Volume of Tank = (Total Microbial Mass*Sewage Flow*Influent BOD)/(MLSS*Daily bod)
BOD Influent given MLSS
Go Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow)
Sewage Flow given MLSS
Go Sewage Flow = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD)
Biological Oxygen Demand influent
Go Biological oxygen demand = (Food to microorganism ratio*Volume of Tank*MLSS)/Sewage Flow
Volume of Tank given Food to Microorganism Ratio
Go Volume of Tank = (Sewage Flow*Influent BOD)/(Food to microorganism ratio*MLSS)
Food to Microorganism Ratio given MLSS
Go Food to microorganism ratio = (Sewage Flow*Influent BOD)/(MLSS*Volume of Tank)
Mixed Liquor Suspended Solid
Go MLSS = (Sewage Flow*Influent BOD)/(Food to microorganism ratio*Volume of Tank)
Sewage Flow given Food to Microorganism Ratio
Go Sewage Flow = (Food to microorganism ratio*Volume of Tank*MLSS)/Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
Go Total Microbial Mass = Daily bod/Food to microorganism ratio
Daily BOD Load given Food to Microorganism Ratio
Go Daily bod = Food to microorganism ratio*Total Microbial Mass
Food to Microorganism Ratio
Go Food to microorganism ratio = Daily bod/Total Microbial Mass
MLSS given Microbial Mass in Aeration System
Go MLSS = (Total Microbial Mass/Volume of Tank)
Volume of Tank given Microbial Mass in Aeration System
Go Volume of Tank = Total Microbial Mass/MLSS
Microbial Mass in Aeration System
Go Total Microbial Mass = MLSS*Volume of Tank
Sewage Flow into Aeration System given BOD Load applied
Go Sewage Flow = Daily bod/Influent BOD
BOD of Influent Sewage given BOD Load applied
Go Influent BOD = Daily bod/Sewage Flow
BOD Load applied to Aeration System
Go Daily bod = Sewage Flow*Influent BOD

Microbial Mass in Aeration System Formula

Total Microbial Mass = MLSS*Volume of Tank
Mt = X*V

What is MLSS ?

Mixed liquor suspended solids (MLSS) is the concentration of suspended solids, in an aeration tank during the activated sludge process, which occurs during the treatment of waste water.

How to Calculate Microbial Mass in Aeration System?

Microbial Mass in Aeration System calculator uses Total Microbial Mass = MLSS*Volume of Tank to calculate the Total Microbial Mass, The Microbial Mass in Aeration System calculates microbial mass when we have prior information of other parameters used. Total Microbial Mass is denoted by Mt symbol.

How to calculate Microbial Mass in Aeration System using this online calculator? To use this online calculator for Microbial Mass in Aeration System, enter MLSS (X) & Volume of Tank (V) and hit the calculate button. Here is how the Microbial Mass in Aeration System calculation can be explained with given input values -> 1.1E+7 = 1.2*9.

FAQ

What is Microbial Mass in Aeration System?
The Microbial Mass in Aeration System calculates microbial mass when we have prior information of other parameters used and is represented as Mt = X*V or Total Microbial Mass = MLSS*Volume of Tank. MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics) & Volume of tank is defined as the capacity of flocculation and mixing tank.
How to calculate Microbial Mass in Aeration System?
The Microbial Mass in Aeration System calculates microbial mass when we have prior information of other parameters used is calculated using Total Microbial Mass = MLSS*Volume of Tank. To calculate Microbial Mass in Aeration System, you need MLSS (X) & Volume of Tank (V). With our tool, you need to enter the respective value for MLSS & Volume of Tank and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Total Microbial Mass?
In this formula, Total Microbial Mass uses MLSS & Volume of Tank. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Total Microbial Mass = Daily bod/Food to microorganism ratio
  • Total Microbial Mass = Daily bod/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!