Peaking Factor given Capacity of Chlorinator at Peak Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Peaking factor = (Chlorine required/(Average flow*8.34*Dosage))
f = (Cl2/(Qa*8.34*D))
This formula uses 4 Variables
Variables Used
Peaking factor - Peaking factor is the ratio of the maximum flow to the average daily flow in a water system.
Chlorine required - (Measured in Kilogram per Second) - Chlorine required means pounds of chlorine required per day.
Average flow - (Measured in Cubic Meter per Second) - Average flow is measured in terms of discharge.
Dosage - (Measured in Kilogram per Cubic Meter) - Dosage used to obtain coliform reduction.
STEP 1: Convert Input(s) to Base Unit
Chlorine required: 10 Kilogram per Day --> 0.000115740740740741 Kilogram per Second (Check conversion here)
Average flow: 3 Cubic Meter per Second --> 3 Cubic Meter per Second No Conversion Required
Dosage: 10 Milligram per Liter --> 0.01 Kilogram per Cubic Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = (Cl2/(Qa*8.34*D)) --> (0.000115740740740741/(3*8.34*0.01))
Evaluating ... ...
f = 0.000462592888652042
STEP 3: Convert Result to Output's Unit
0.000462592888652042 --> No Conversion Required
FINAL ANSWER
0.000462592888652042 0.000463 <-- Peaking factor
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

11 Design of a Chlorination System for Wastewater Disinfection Calculators

Residence Time given Number of Coliform Organisms at Any Particular Time
Go Residence time = ((Number of Coliform/Number of coliform)^(1/3)-1)/(0.23*Chlorine residual)
Total Chlorine Residual at Any Particular Time
Go Chlorine residual = ((Number of Coliform/Number of coliform)^(1/3)-1)/(0.23*Residence time)
Number of Coliform Organisms at Any Initial Time
Go Number of Coliform = (Number of coliform/(1+0.23*Chlorine residual*Residence time)^(-3))
Number of Coliform Organisms at Any Particular Time
Go Number of coliform = Number of Coliform*(1+0.23*Chlorine residual*Residence time)^(-3)
Peaking Factor given Capacity of Chlorinator at Peak Flow
Go Peaking factor = (Chlorine required/(Average flow*8.34*Dosage))
Average Flow given Capacity of Chlorinator at Peak Flow
Go Average flow = (Chlorine required/(Dosage*Peaking factor*8.34))
Dosage Used given Capacity of Chlorinator at Peak Flow
Go Dosage = (Chlorine required/(Peaking factor*Average flow*8.34))
Capacity of Chlorinator at Peak Flow
Go Chlorine required = Dosage*Average flow*8.34*Peaking factor
Average Flow given Average Daily Consumption of Chlorine
Go Average flow = (Chlorine required/(Dosage*8.34))
Dosage Used given Average Daily Consumption of Chlorine
Go Dosage = (Chlorine required/(8.34*Average flow))
Average Daily Consumption of Chlorine
Go Chlorine required = Dosage*Average flow*8.34

Peaking Factor given Capacity of Chlorinator at Peak Flow Formula

Peaking factor = (Chlorine required/(Average flow*8.34*Dosage))
f = (Cl2/(Qa*8.34*D))

What is coliform ?

Coliform bacteria are defined as Rod shaped Gram-negative non-spore forming and motile or non-motile bacteria which can ferment lactose with the production of acid and gas when incubated at 35–37°C.

How to Calculate Peaking Factor given Capacity of Chlorinator at Peak Flow?

Peaking Factor given Capacity of Chlorinator at Peak Flow calculator uses Peaking factor = (Chlorine required/(Average flow*8.34*Dosage)) to calculate the Peaking factor, The Peaking Factor given Capacity of Chlorinator at Peak Flow calculates the peaking factor when we have prior information of average flow , chlorine required and dosage used to obtain coliform. Peaking factor is denoted by f symbol.

How to calculate Peaking Factor given Capacity of Chlorinator at Peak Flow using this online calculator? To use this online calculator for Peaking Factor given Capacity of Chlorinator at Peak Flow, enter Chlorine required (Cl2), Average flow (Qa) & Dosage (D) and hit the calculate button. Here is how the Peaking Factor given Capacity of Chlorinator at Peak Flow calculation can be explained with given input values -> 0.000463 = (0.000115740740740741/(3*8.34*0.01)).

FAQ

What is Peaking Factor given Capacity of Chlorinator at Peak Flow?
The Peaking Factor given Capacity of Chlorinator at Peak Flow calculates the peaking factor when we have prior information of average flow , chlorine required and dosage used to obtain coliform and is represented as f = (Cl2/(Qa*8.34*D)) or Peaking factor = (Chlorine required/(Average flow*8.34*Dosage)). Chlorine required means pounds of chlorine required per day, Average flow is measured in terms of discharge & Dosage used to obtain coliform reduction.
How to calculate Peaking Factor given Capacity of Chlorinator at Peak Flow?
The Peaking Factor given Capacity of Chlorinator at Peak Flow calculates the peaking factor when we have prior information of average flow , chlorine required and dosage used to obtain coliform is calculated using Peaking factor = (Chlorine required/(Average flow*8.34*Dosage)). To calculate Peaking Factor given Capacity of Chlorinator at Peak Flow, you need Chlorine required (Cl2), Average flow (Qa) & Dosage (D). With our tool, you need to enter the respective value for Chlorine required, Average flow & Dosage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!