Percent Stabilization Solution

STEP 0: Pre-Calculation Summary
Formula Used
Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100
%S = ((BODin-BODout-1.42*Px)/BODin)*100
This formula uses 4 Variables
Variables Used
Percent stabilization - Percent stabilization is defined as percentage of bod removal.
BOD in - (Measured in Kilogram per Second) - BOD in means the amount of dissolved oxygen enter anaerobic digester.
BOD out - (Measured in Kilogram per Second) - BOD out means the amount of dissolved oxygen exits anaerobic digester.
Volatile Solids produced - (Measured in Kilogram per Second) - Volatile solids produced is defined in terms of mass flow rate.
STEP 1: Convert Input(s) to Base Unit
BOD in: 150 Kilogram per Day --> 0.00173611111111111 Kilogram per Second (Check conversion here)
BOD out: 5 Kilogram per Day --> 5.78703703703704E-05 Kilogram per Second (Check conversion here)
Volatile Solids produced: 100 Kilogram per Day --> 0.00115740740740741 Kilogram per Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
%S = ((BODin-BODout-1.42*Px)/BODin)*100 --> ((0.00173611111111111-5.78703703703704E-05-1.42*0.00115740740740741)/0.00173611111111111)*100
Evaluating ... ...
%S = 1.99999999999973
STEP 3: Convert Result to Output's Unit
1.99999999999973 --> No Conversion Required
FINAL ANSWER
1.99999999999973 2 <-- Percent stabilization
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

20 Design of an Anaerobic Digester Calculators

Endogenous Coefficient given Quantity of Volatile Solids
Go Endogenous coefficient = (1/Mean Cell Residence Time)-(Yield coefficient*(BOD in-BOD out)/(Volatile Solids produced*Mean Cell Residence Time))
Mean Cell Residence Time given Quantity of Volatile Solids
Go Mean Cell Residence Time = (1/Endogenous coefficient)-(Yield coefficient*(BOD in-BOD out)/(Volatile Solids produced*Endogenous coefficient))
Yield Coefficient given Quantity of Volatile Solids
Go Yield coefficient = (Volatile Solids produced*(1-Mean Cell Residence Time*Endogenous coefficient))/(BOD in-BOD out)
Quantity of Volatile Solids Produced Each Day
Go Volatile Solids produced = (Yield coefficient*(BOD in-BOD out))/(1-Endogenous coefficient*Mean Cell Residence Time)
BOD Out given Quantity of Volatile Solids
Go BOD out = BOD in-(Volatile Solids produced/Yield coefficient)*(1-Endogenous coefficient*Mean Cell Residence Time)
BOD in given Quantity of Volatile Solids
Go BOD in = (Volatile Solids produced/Yield coefficient)*(1-Endogenous coefficient*Mean Cell Residence Time)+BOD out
Volatile Solids produced given Percent Stabilization
Go Volatile Solids produced = (1/1.42)*(BOD in-BOD out-((Percent stabilization*BOD in)/100))
BOD Out given Percent Stabilization
Go BOD out = (BOD in*100-142*Volatile Solids produced-Percent stabilization*BOD in)/100
Percent Stabilization
Go Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100
BOD in given Percent Stabilization
Go BOD in = (BOD out*100+142*Volatile Solids produced)/(100-Percent stabilization)
Volatile Solids produced given Volume of Methane Gas produced
Go Volatile Solids produced = (1/1.42)*(BOD in-BOD out-(Volume of methane/5.62))
BOD Out given Volume of Methane Gas Produced
Go BOD out = (BOD in-(Volume of methane/5.62)-(1.42*Volatile Solids produced))
BOD in given Volume of Methane Gas Produced
Go BOD in = (Volume of methane/5.62)+BOD out+(1.42*Volatile Solids produced)
Volume of Methane Gas Produced at Standard Conditions
Go Volume of methane = 5.62*(BOD in-BOD out-1.42*Volatile Solids produced)
Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
Go Influent Sludge Flow Rate = (Volume/Hydraulic retention time)
Hydraulic Retention Time given Volume Required for Anaerobic Digester
Go Hydraulic Retention Time = (Volume/Influent Sludge Flow Rate)
Volume Required for Anaerobic Digester
Go Volume = (Hydraulic retention time*Influent Sludge Flow Rate)
Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester
Go Volumetric Flow Rate = (BOD per day/Volumetric loading)
BOD Per Day given Volumetric Loading in Anaerobic Digester
Go BOD per day = (Volumetric loading*Volumetric Flow Rate)
Volumetric Loading in Anaerobic Digester
Go Volumetric loading = (BOD per day/Volumetric Flow Rate)

Percent Stabilization Formula

Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100
%S = ((BODin-BODout-1.42*Px)/BODin)*100

What is BOD ?

Biochemical oxygen demand is the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water sample at certain temperature over a specific time period.

How to Calculate Percent Stabilization?

Percent Stabilization calculator uses Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100 to calculate the Percent stabilization, The Percent Stabilization calculates the stabilization in fraction when we have prior information of volatile solids produced and bod . Percent stabilization is denoted by %S symbol.

How to calculate Percent Stabilization using this online calculator? To use this online calculator for Percent Stabilization, enter BOD in (BODin), BOD out (BODout) & Volatile Solids produced (Px) and hit the calculate button. Here is how the Percent Stabilization calculation can be explained with given input values -> -635 = ((0.00173611111111111-5.78703703703704E-05-1.42*0.00115740740740741)/0.00173611111111111)*100.

FAQ

What is Percent Stabilization?
The Percent Stabilization calculates the stabilization in fraction when we have prior information of volatile solids produced and bod and is represented as %S = ((BODin-BODout-1.42*Px)/BODin)*100 or Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100. BOD in means the amount of dissolved oxygen enter anaerobic digester, BOD out means the amount of dissolved oxygen exits anaerobic digester & Volatile solids produced is defined in terms of mass flow rate.
How to calculate Percent Stabilization?
The Percent Stabilization calculates the stabilization in fraction when we have prior information of volatile solids produced and bod is calculated using Percent stabilization = ((BOD in-BOD out-1.42*Volatile Solids produced)/BOD in)*100. To calculate Percent Stabilization, you need BOD in (BODin), BOD out (BODout) & Volatile Solids produced (Px). With our tool, you need to enter the respective value for BOD in, BOD out & Volatile Solids produced and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!