Pitch of spiral reinforcement in terms of Volume of Core Solution

STEP 0: Pre-Calculation Summary
Formula Used
Pitch of spiral reinforcement = (4*Volume of core)/(pi*Diameter of core*Diameter of core)
p = (4*Vc)/(pi*Dc*Dc)
This formula uses 1 Constants, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Pitch of spiral reinforcement - (Measured in Meter) - Pitch of spiral reinforcement gives us a certain amount of flexural reinforcement.
Volume of core - (Measured in Cubic Meter) - Volume of core is the volume of the core of a given spiral reinforcement.
Diameter of core - (Measured in Meter) - Diameter of core is the diameter of the core of a given spiral reinforcement.
STEP 1: Convert Input(s) to Base Unit
Volume of core: 3000 Cubic Meter --> 3000 Cubic Meter No Conversion Required
Diameter of core: 100 Meter --> 100 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
p = (4*Vc)/(pi*Dc*Dc) --> (4*3000)/(pi*100*100)
Evaluating ... ...
p = 0.381971863420549
STEP 3: Convert Result to Output's Unit
0.381971863420549 Meter -->381.971863420549 Millimeter (Check conversion here)
FINAL ANSWER
381.971863420549 Millimeter <-- Pitch of spiral reinforcement
(Calculation completed in 00.031 seconds)

Credits

Created by Pranav More
Vellore Institute of Technology, Vellore (VIT, Vellore), Vellore
Pranav More has created this Calculator and 10+ more calculators!
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 800+ more calculators!

10+ Short Axially Loaded Columns with Helical Ties Calculators

Area of longitudinal reinforcement for columns given factored axial load in spiral columns
Area of longitudinal reinforcement for columns = (((Factored axial load)/(1.05))-(0.4*Characteristic compressive strength*Area of concrete))/(0.67*Characteristic strength compressive reinforcement) Go
Characteristic strength of the compression reinforcement given factored load in spiral columns
Characteristic strength compressive reinforcement = ((Factored axial load/1.05)-(0.4*Characteristic compressive strength*Area of concrete))/(0.67*Area of longitudinal reinforcement for columns) Go
Characteristic compressive strength of concrete given factored axial load in spiral columns
Characteristic compressive strength = (0.95*Factored axial load-0.67*Characteristic strength compressive reinforcement*Area of longitudinal reinforcement for columns)/(0.4*Area of concrete) Go
Area of concrete given factored axial load in spiral columns
Area of concrete = (0.95*Factored axial load-0.67*Characteristic strength compressive reinforcement*Area of longitudinal reinforcement for columns)/(0.4*Characteristic compressive strength) Go
Factored Axial Load on the Member of the spiral columns
Factored Load = 1.05*(0.4*Characteristic compressive strength*Area of concrete+0.67*Characteristic strength compressive reinforcement*Area of longitudinal reinforcement for columns) Go
Diameter of the spiral reinforcement in terms of Volume of helical reinforcement in one loop
Diameter of spiral reinforcement = Diameter of core-((Volume of helical reinforcement)/(pi*Area of cross section of spiral reinforcement)) Go
Diameter of the core in terms of Volume of helical reinforcement in one loop
Diameter of core = ((Volume of helical reinforcement)/(pi*Area of cross section of spiral reinforcement))+Diameter of spiral reinforcement Go
Area of cross-section of spiral reinforcement when Volume is established
Area of cross section of spiral reinforcement = Volume of helical reinforcement/pi*(Diameter of core-Diameter of spiral reinforcement) Go
Volume of helical reinforcement in one loop
Volume of helical reinforcement = pi*(Diameter of core-Diameter of spiral reinforcement)*Area of cross section of spiral reinforcement Go
Volume of core in Short Axially Loaded Columns with Helical Ties
Volume of core = (pi/4)*((Diameter of core)^(2))*Pitch of spiral reinforcement Go

Pitch of spiral reinforcement in terms of Volume of Core Formula

Pitch of spiral reinforcement = (4*Volume of core)/(pi*Diameter of core*Diameter of core)
p = (4*Vc)/(pi*Dc*Dc)

What is the use of spiral pitch?

The spiral pitch will be used to ensure the clear distance between the spirals is between the 1" and 3" required. Note: This is not based on ACI code, just standard practice.

How to Calculate Pitch of spiral reinforcement in terms of Volume of Core?

Pitch of spiral reinforcement in terms of Volume of Core calculator uses Pitch of spiral reinforcement = (4*Volume of core)/(pi*Diameter of core*Diameter of core) to calculate the Pitch of spiral reinforcement, The Pitch of spiral reinforcement in terms of Volume of Core formula is defined as a certain amount of flexural reinforcement. Pitch of spiral reinforcement is denoted by p symbol.

How to calculate Pitch of spiral reinforcement in terms of Volume of Core using this online calculator? To use this online calculator for Pitch of spiral reinforcement in terms of Volume of Core, enter Volume of core (Vc) & Diameter of core (Dc) and hit the calculate button. Here is how the Pitch of spiral reinforcement in terms of Volume of Core calculation can be explained with given input values -> 381.9719 = (4*3000)/(pi*100*100).

FAQ

What is Pitch of spiral reinforcement in terms of Volume of Core?
The Pitch of spiral reinforcement in terms of Volume of Core formula is defined as a certain amount of flexural reinforcement and is represented as p = (4*Vc)/(pi*Dc*Dc) or Pitch of spiral reinforcement = (4*Volume of core)/(pi*Diameter of core*Diameter of core). Volume of core is the volume of the core of a given spiral reinforcement & Diameter of core is the diameter of the core of a given spiral reinforcement.
How to calculate Pitch of spiral reinforcement in terms of Volume of Core?
The Pitch of spiral reinforcement in terms of Volume of Core formula is defined as a certain amount of flexural reinforcement is calculated using Pitch of spiral reinforcement = (4*Volume of core)/(pi*Diameter of core*Diameter of core). To calculate Pitch of spiral reinforcement in terms of Volume of Core, you need Volume of core (Vc) & Diameter of core (Dc). With our tool, you need to enter the respective value for Volume of core & Diameter of core and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.