Polar Moment of Inertia for Axial Buckling Load for Warped Section Solution

STEP 0: Pre-Calculation Summary
Formula Used
Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2))
Ip = A/PBuckling Load*(G*J+((pi^2*E*Cw)/L^2))
This formula uses 1 Constants, 8 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Polar Moment of Inertia - (Measured in Millimeter⁴) - The Polar Moment of Inertia is a measure of an object’s capacity to oppose or resist torsion when some amount of torque is applied to it on a specified axis.
Column Cross-Sectional Area - (Measured in Square Millimeter) - Column Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional object is sliced perpendicular to some specified axis at a point.
Buckling Load - (Measured in Newton) - The Buckling Load is the load at which the column starts buckling. The buckling load of a given material depends on the Slenderness ratio, Area of a cross-section, and Modulus of Elasticity.
Shear Modulus of Elasticity - (Measured in Megapascal) - The Shear Modulus of Elasticity is the measure of the rigidity of the body, given by the ratio of shear stress to shear strain.
Torsional Constant - Torsional Constant is a geometrical property of a bar's cross-section which is involved in the relationship between the angle of twist and applied torque along the axis of the bar.
Modulus of Elasticity - (Measured in Megapascal) - The Modulus of Elasticity is the measure of the stiffness of a material. It is the slope of stress and strain diagram up to the limit of proportionality.
Warping Constant - (Measured in Kilogram Square Meter) - Warping Constant is often referred to as the warping moment of inertia. It is a quantity derived from a cross-section.
Effective Length of Column - (Measured in Millimeter) - The Effective Length of Column can be defined as the length of an equivalent pin-ended column having the same load-carrying capacity as the member under consideration.
STEP 1: Convert Input(s) to Base Unit
Column Cross-Sectional Area: 700 Square Millimeter --> 700 Square Millimeter No Conversion Required
Buckling Load: 5 Newton --> 5 Newton No Conversion Required
Shear Modulus of Elasticity: 230 Megapascal --> 230 Megapascal No Conversion Required
Torsional Constant: 10 --> No Conversion Required
Modulus of Elasticity: 50 Megapascal --> 50 Megapascal No Conversion Required
Warping Constant: 10 Kilogram Square Meter --> 10 Kilogram Square Meter No Conversion Required
Effective Length of Column: 3000 Millimeter --> 3000 Millimeter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ip = A/PBuckling Load*(G*J+((pi^2*E*Cw)/L^2)) --> 700/5*(230*10+((pi^2*50*10)/3000^2))
Evaluating ... ...
Ip = 322000.07676359
STEP 3: Convert Result to Output's Unit
3.2200007676359E-07 Meter⁴ -->322000.07676359 Millimeter⁴ (Check conversion here)
FINAL ANSWER
322000.07676359 322000.1 Millimeter⁴ <-- Polar Moment of Inertia
(Calculation completed in 00.020 seconds)

Credits

Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verified by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has verified this Calculator and 1700+ more calculators!

7 Elastic Flexural Buckling of Columns Calculators

Cross-Sectional Area given Axial Buckling Load for Warped Section
Go Column Cross-Sectional Area = (Buckling Load*Polar Moment of Inertia)/(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2))
Polar Moment of Inertia for Axial Buckling Load for Warped Section
Go Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2))
Axial Buckling Load for Warped Section
Go Buckling Load = (Column Cross-Sectional Area/Polar Moment of Inertia)*(Shear Modulus of Elasticity*Torsional Constant+(pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2)
Shear Modulus of Elasticity given Torsional Buckling Load for Pin Ended Columns
Go Shear Modulus of Elasticity = (Buckling Load*Polar Moment of Inertia)/(Torsional Constant*Column Cross-Sectional Area)
Cross-Sectional Area given Torsional Buckling Load for Pin Ended Columns
Go Column Cross-Sectional Area = (Buckling Load*Polar Moment of Inertia)/(Shear Modulus of Elasticity*Torsional Constant)
Torsional Buckling Load for Pin Ended Columns
Go Buckling Load = (Shear Modulus of Elasticity*Torsional Constant*Column Cross-Sectional Area)/Polar Moment of Inertia
Polar Moment of Inertia for Pin Ended Columns
Go Polar Moment of Inertia = (Shear Modulus of Elasticity*Torsional Constant*Column Cross-Sectional Area)/Buckling Load

Polar Moment of Inertia for Axial Buckling Load for Warped Section Formula

Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2))
Ip = A/PBuckling Load*(G*J+((pi^2*E*Cw)/L^2))

What is Buckling Load in Column?

Buckling can be defined as the sudden large deformation of the structure due to a slight increase of an existing load under which the structure exhibited little deformation, before the load was increased.

When does Lateral Torsional Buckling occur?

Lateral torsional buckling may occur in an unrestrained beam. A beam is considered to be unrestrained when its compression flange is free to displace laterally and rotate. When an applied load causes both lateral displacement and twisting of a member lateral torsional buckling has occurred.

How to Calculate Polar Moment of Inertia for Axial Buckling Load for Warped Section?

Polar Moment of Inertia for Axial Buckling Load for Warped Section calculator uses Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2)) to calculate the Polar Moment of Inertia, The Polar Moment of Inertia for Axial Buckling Load for Warped Section formula is defined as a measurement of a capacity to oppose torsion. It is required to compute the twist of a column subjected to torque. Polar Moment of Inertia is denoted by Ip symbol.

How to calculate Polar Moment of Inertia for Axial Buckling Load for Warped Section using this online calculator? To use this online calculator for Polar Moment of Inertia for Axial Buckling Load for Warped Section, enter Column Cross-Sectional Area (A), Buckling Load (PBuckling Load), Shear Modulus of Elasticity (G), Torsional Constant (J), Modulus of Elasticity (E), Warping Constant (Cw) & Effective Length of Column (L) and hit the calculate button. Here is how the Polar Moment of Inertia for Axial Buckling Load for Warped Section calculation can be explained with given input values -> 3.2E+17 = 0.0007/5*(230000000*10+((pi^2*50000000*10)/3^2)).

FAQ

What is Polar Moment of Inertia for Axial Buckling Load for Warped Section?
The Polar Moment of Inertia for Axial Buckling Load for Warped Section formula is defined as a measurement of a capacity to oppose torsion. It is required to compute the twist of a column subjected to torque and is represented as Ip = A/PBuckling Load*(G*J+((pi^2*E*Cw)/L^2)) or Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2)). Column Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional object is sliced perpendicular to some specified axis at a point, The Buckling Load is the load at which the column starts buckling. The buckling load of a given material depends on the Slenderness ratio, Area of a cross-section, and Modulus of Elasticity, The Shear Modulus of Elasticity is the measure of the rigidity of the body, given by the ratio of shear stress to shear strain, Torsional Constant is a geometrical property of a bar's cross-section which is involved in the relationship between the angle of twist and applied torque along the axis of the bar, The Modulus of Elasticity is the measure of the stiffness of a material. It is the slope of stress and strain diagram up to the limit of proportionality, Warping Constant is often referred to as the warping moment of inertia. It is a quantity derived from a cross-section & The Effective Length of Column can be defined as the length of an equivalent pin-ended column having the same load-carrying capacity as the member under consideration.
How to calculate Polar Moment of Inertia for Axial Buckling Load for Warped Section?
The Polar Moment of Inertia for Axial Buckling Load for Warped Section formula is defined as a measurement of a capacity to oppose torsion. It is required to compute the twist of a column subjected to torque is calculated using Polar Moment of Inertia = Column Cross-Sectional Area/Buckling Load*(Shear Modulus of Elasticity*Torsional Constant+((pi^2*Modulus of Elasticity*Warping Constant)/Effective Length of Column^2)). To calculate Polar Moment of Inertia for Axial Buckling Load for Warped Section, you need Column Cross-Sectional Area (A), Buckling Load (PBuckling Load), Shear Modulus of Elasticity (G), Torsional Constant (J), Modulus of Elasticity (E), Warping Constant (Cw) & Effective Length of Column (L). With our tool, you need to enter the respective value for Column Cross-Sectional Area, Buckling Load, Shear Modulus of Elasticity, Torsional Constant, Modulus of Elasticity, Warping Constant & Effective Length of Column and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Polar Moment of Inertia?
In this formula, Polar Moment of Inertia uses Column Cross-Sectional Area, Buckling Load, Shear Modulus of Elasticity, Torsional Constant, Modulus of Elasticity, Warping Constant & Effective Length of Column. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Polar Moment of Inertia = (Shear Modulus of Elasticity*Torsional Constant*Column Cross-Sectional Area)/Buckling Load
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!