Q Factor for Parallel RLC Circuit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance))
Q|| = R*(sqrt(C/L))
This formula uses 1 Functions, 4 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Parallel RLC Quality Factor - Parallel RLC Quality Factor is defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation in a Parallel RLC Circuit.
Resistance - (Measured in Ohm) - Resistance is a measure of the opposition to current flow in an electrical circuit. Resistance is measured in ohms, symbolized by the Greek letter omega (Ω).
Capacitance - (Measured in Farad) - Capacitance is the capability of a material object or device to store electric charge. It is measured by the change in charge in response to a difference in electric potential.
Inductance - (Measured in Henry) - Inductance is the tendency of an electrical conductor to oppose a change in the electric current flowing through it. The flow of electric current creates a magnetic field around the conductor.
STEP 1: Convert Input(s) to Base Unit
Resistance: 60 Ohm --> 60 Ohm No Conversion Required
Capacitance: 350 Microfarad --> 0.00035 Farad (Check conversion here)
Inductance: 0.79 Millihenry --> 0.00079 Henry (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q|| = R*(sqrt(C/L)) --> 60*(sqrt(0.00035/0.00079))
Evaluating ... ...
Q|| = 39.9366587092706
STEP 3: Convert Result to Output's Unit
39.9366587092706 --> No Conversion Required
FINAL ANSWER
39.9366587092706 39.93666 <-- Parallel RLC Quality Factor
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

5 Power Factor & Q Factor Calculators

Q Factor for Series RLC Circuit
Go Series RLC Quality Factor = 1/(Resistance)*(sqrt(Inductance/Capacitance))
Q Factor for Parallel RLC Circuit
Go Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance))
Power Factor given Power
Go Power Factor = Real Power/(Voltage*Current)
Power Factor given Power Factor Angle
Go Power Factor = cos(Phase Difference)
Power Factor given Impedance
Go Power Factor = Resistance/Impedance

25 AC Circuit Design Calculators

Resistance for Series RLC Circuit given Q Factor
Go Resistance = sqrt(Inductance)/(Series RLC Quality Factor*sqrt(Capacitance))
Line to Neutral Current using Reactive Power
Go Line to Neutral Current = Reactive Power/(3*Line to Neutral Voltage*sin(Phase Difference))
RMS Current using Reactive Power
Go Root Mean Square Current = Reactive Power/(Root Mean Square Voltage*sin(Phase Difference))
Line to Neutral Current using Real Power
Go Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage)
RMS Current using Real Power
Go Root Mean Square Current = Real Power/(Root Mean Square Voltage*cos(Phase Difference))
Resistance for Parallel RLC Circuit using Q Factor
Go Resistance = Parallel RLC Quality Factor/(sqrt(Capacitance/Inductance))
Resonant Frequency for RLC circuit
Go Resonant Frequency = 1/(2*pi*sqrt(Inductance*Capacitance))
Electric Current using Reactive Power
Go Current = Reactive Power/(Voltage*sin(Phase Difference))
Electric Current using Real Power
Go Current = Real Power/(Voltage*cos(Phase Difference))
Power in Single-Phase AC Circuits
Go Real Power = Voltage*Current*cos(Phase Difference)
Inductance for Parallel RLC Circuit using Q Factor
Go Inductance = (Capacitance*Resistance^2)/(Parallel RLC Quality Factor^2)
Capacitance for Parallel RLC Circuit using Q Factor
Go Capacitance = (Inductance*Parallel RLC Quality Factor^2)/Resistance^2
Capacitance for Series RLC Circuit given Q Factor
Go Capacitance = Inductance/(Series RLC Quality Factor^2*Resistance^2)
Inductance for Series RLC Circuit given Q Factor
Go Inductance = Capacitance*Series RLC Quality Factor^2*Resistance^2
Capacitance given Cut off Frequency
Go Capacitance = 1/(2*Resistance*pi*Cut-off Frequency)
Cut Off Frequency for RC circuit
Go Cut-off Frequency = 1/(2*pi*Capacitance*Resistance)
Complex Power
Go Complex Power = sqrt(Real Power^2+Reactive Power^2)
Complex Power given Power Factor
Go Complex Power = Real Power/cos(Phase Difference)
Current using Power Factor
Go Current = Real Power/(Power Factor*Voltage)
Current using Complex Power
Go Current = sqrt(Complex Power/Impedance)
Frequency using Time Period
Go Natural Frequency = 1/(2*pi*Time Period)
Capacitance using Time Constant
Go Capacitance = Time Constant/Resistance
Resistance using Time Constant
Go Resistance = Time Constant/Capacitance
Impedance given Complex Power and Voltage
Go Impedance = (Voltage^2)/Complex Power
Impedance given Complex Power and Current
Go Impedance = Complex Power/(Current^2)

Q Factor for Parallel RLC Circuit Formula

Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance))
Q|| = R*(sqrt(C/L))

What is Q factor?

Q-factor is nothing but the relationship between stored energy and the rate of energy in electrical components, devices. The ratio of the reactance in ohms divided by the resistance in ohms is defined as the quality factor.

How to Calculate Q Factor for Parallel RLC Circuit?

Q Factor for Parallel RLC Circuit calculator uses Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance)) to calculate the Parallel RLC Quality Factor, The Q Factor for Parallel RLC Circuit formula is defined as a dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation. Parallel RLC Quality Factor is denoted by Q|| symbol.

How to calculate Q Factor for Parallel RLC Circuit using this online calculator? To use this online calculator for Q Factor for Parallel RLC Circuit, enter Resistance (R), Capacitance (C) & Inductance (L) and hit the calculate button. Here is how the Q Factor for Parallel RLC Circuit calculation can be explained with given input values -> 39.93666 = 60*(sqrt(0.00035/0.00079)).

FAQ

What is Q Factor for Parallel RLC Circuit?
The Q Factor for Parallel RLC Circuit formula is defined as a dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation and is represented as Q|| = R*(sqrt(C/L)) or Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance)). Resistance is a measure of the opposition to current flow in an electrical circuit. Resistance is measured in ohms, symbolized by the Greek letter omega (Ω), Capacitance is the capability of a material object or device to store electric charge. It is measured by the change in charge in response to a difference in electric potential & Inductance is the tendency of an electrical conductor to oppose a change in the electric current flowing through it. The flow of electric current creates a magnetic field around the conductor.
How to calculate Q Factor for Parallel RLC Circuit?
The Q Factor for Parallel RLC Circuit formula is defined as a dimensionless parameter that describes how underdamped an oscillator or resonator is. It is approximately defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation is calculated using Parallel RLC Quality Factor = Resistance*(sqrt(Capacitance/Inductance)). To calculate Q Factor for Parallel RLC Circuit, you need Resistance (R), Capacitance (C) & Inductance (L). With our tool, you need to enter the respective value for Resistance, Capacitance & Inductance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!