Rs for DC Operation Full Wave Solution

STEP 0: Pre-Calculation Summary
Formula Used
Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rf = (Vrms*Sdc)-Rm-(2*Rd)
This formula uses 5 Variables
Variables Used
Shunt Meter Resistance Full Wave - (Measured in Ohm) - Shunt Meter Resistance Full Wave is the value of Shunt Meter resistance connected parallel to each other attached to the permanent magnet moving coil based voltmeter.
Voltage RMS Value - (Measured in Volt) - Voltage RMS Value is the rms value of AC voltage.
Sensitivity of DC Meter - (Measured in Ohm Per Volt) - Sensitivity of DC Meter is the ability of meter to detect small changes in current or voltage.
Resistance of Multiplier - (Measured in Ohm) - Resistance of Multiplier sets the range of the meter by determining the current sensitivity.
Resistance of Diode - (Measured in Ohm) - Resistance of Diode is the value of the diode resistance for the diodes used in rectifier instrument.
STEP 1: Convert Input(s) to Base Unit
Voltage RMS Value: 7.07 Volt --> 7.07 Volt No Conversion Required
Sensitivity of DC Meter: 9 Ohm Per Volt --> 9 Ohm Per Volt No Conversion Required
Resistance of Multiplier: 13 Ohm --> 13 Ohm No Conversion Required
Resistance of Diode: 0.75 Ohm --> 0.75 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rf = (Vrms*Sdc)-Rm-(2*Rd) --> (7.07*9)-13-(2*0.75)
Evaluating ... ...
Rf = 49.13
STEP 3: Convert Result to Output's Unit
49.13 Ohm --> No Conversion Required
FINAL ANSWER
49.13 Ohm <-- Shunt Meter Resistance Full Wave
(Calculation completed in 00.020 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

11 Rectifier Type Voltmeter Calculators

Rs for DC Operation Full Wave
Go Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rs for AC Operation Full Wave
Go Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of AC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rs for DC Operation Half Wave
Go Shunt Meter Resistance Half Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-Resistance of Diode
Rs for AC Operation Half Wave
Go Shunt Meter Resistance Half Wave = (Voltage RMS Value*Sensitivity of AC Meter)-Resistance of Multiplier-Resistance of Diode
AC Voltage
Go Meter Voltage = Peak Value of Voltage*sin(Angular Frequency*Time)
Vrms value
Go Voltage RMS Value = Peak Value of Voltage/sqrt(2)
Vav of Half Wave Rectifier
Go Average Voltmeter Half Rectifier = 0.45*Voltage RMS Value
DC Meter Sensitivity
Go Sensitivity of DC Meter = 1/Full Scale Current Deflection
AC Meter Sensitivity for Half Wave Rectifier
Go Sensitivity of AC Meter = 0.45*Sensitivity of DC Meter
Vav of Full Scale Rectifier
Go Average Voltage Full Rectifier = 0.9*Voltage RMS Value
AC Meter Sensitivity for Full Wave Rectifier
Go Sensitivity of AC Meter = 0.9*Sensitivity of DC Meter

Rs for DC Operation Full Wave Formula

Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rf = (Vrms*Sdc)-Rm-(2*Rd)

How to calculate Rs?

In a full-wave rectifier, two diodes are used for the operation. Therefore, we subtract the value of two diode resistances, along with meter resistance, from the total resistance. Total resistance is calculated using DC sensitivity since the instrument is in DC operation mode.

How to Calculate Rs for DC Operation Full Wave?

Rs for DC Operation Full Wave calculator uses Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode) to calculate the Shunt Meter Resistance Full Wave, Rs for DC Operation Full Wave formula calculates the value of series resistance for a full-wave rectifier type instrument while in DC operation mode. Shunt Meter Resistance Full Wave is denoted by Rf symbol.

How to calculate Rs for DC Operation Full Wave using this online calculator? To use this online calculator for Rs for DC Operation Full Wave, enter Voltage RMS Value (Vrms), Sensitivity of DC Meter (Sdc), Resistance of Multiplier (Rm) & Resistance of Diode (Rd) and hit the calculate button. Here is how the Rs for DC Operation Full Wave calculation can be explained with given input values -> 49.13 = (7.07*9)-13-(2*0.75).

FAQ

What is Rs for DC Operation Full Wave?
Rs for DC Operation Full Wave formula calculates the value of series resistance for a full-wave rectifier type instrument while in DC operation mode and is represented as Rf = (Vrms*Sdc)-Rm-(2*Rd) or Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode). Voltage RMS Value is the rms value of AC voltage, Sensitivity of DC Meter is the ability of meter to detect small changes in current or voltage, Resistance of Multiplier sets the range of the meter by determining the current sensitivity & Resistance of Diode is the value of the diode resistance for the diodes used in rectifier instrument.
How to calculate Rs for DC Operation Full Wave?
Rs for DC Operation Full Wave formula calculates the value of series resistance for a full-wave rectifier type instrument while in DC operation mode is calculated using Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode). To calculate Rs for DC Operation Full Wave, you need Voltage RMS Value (Vrms), Sensitivity of DC Meter (Sdc), Resistance of Multiplier (Rm) & Resistance of Diode (Rd). With our tool, you need to enter the respective value for Voltage RMS Value, Sensitivity of DC Meter, Resistance of Multiplier & Resistance of Diode and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Shunt Meter Resistance Full Wave?
In this formula, Shunt Meter Resistance Full Wave uses Voltage RMS Value, Sensitivity of DC Meter, Resistance of Multiplier & Resistance of Diode. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of AC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!