Two parallel Isothermal Cylinders placed in Infinite medium Solution

STEP 0: Pre-Calculation Summary
Formula Used
Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2))
S = (2*pi*Lc)/acosh((4*d^2-D1^2-D2^2)/(2*D1*D2))
This formula uses 1 Constants, 2 Functions, 5 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
cosh - The hyperbolic cosine function is a mathematical function that is defined as the ratio of the sum of the exponential functions of x and negative x to 2., cosh(Number)
acosh - Hyperbolic cosine function, is a function that takes a real number as an input and returns the angle whose hyperbolic cosine is that number., acosh(Number)
Variables Used
Conduction Shape Factor - (Measured in Meter) - Conduction shape factor is defined as the value used to determine the heat transfer rate for the configurations which are very complex and require high calculation time.
Length of Cylinder - (Measured in Meter) - Length of Cylinder is the vertical height of the Cylinder.
Distance Between Centers - (Measured in Meter) - Distance between centers is the distance between two centers of circle.
Diameter of Cylinder 1 - (Measured in Meter) - Diameter of Cylinder 1 is the diameter of the first cylinder.
Diameter of Cylinder 2 - (Measured in Meter) - Diameter of Cylinder 2 is the diameter of the second cylinder.
STEP 1: Convert Input(s) to Base Unit
Length of Cylinder: 4 Meter --> 4 Meter No Conversion Required
Distance Between Centers: 10.1890145 Meter --> 10.1890145 Meter No Conversion Required
Diameter of Cylinder 1: 5.1 Meter --> 5.1 Meter No Conversion Required
Diameter of Cylinder 2: 13.739222 Meter --> 13.739222 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
S = (2*pi*Lc)/acosh((4*d^2-D1^2-D2^2)/(2*D1*D2)) --> (2*pi*4)/acosh((4*10.1890145^2-5.1^2-13.739222^2)/(2*5.1*13.739222))
Evaluating ... ...
S = 27.9999991358431
STEP 3: Convert Result to Output's Unit
27.9999991358431 Meter --> No Conversion Required
FINAL ANSWER
27.9999991358431 28 Meter <-- Conduction Shape Factor
(Calculation completed in 00.020 seconds)

Credits

Created by Ravi Khiyani
Shri Govindram Seksaria Institute of Technology and Science (SGSITS), Indore
Ravi Khiyani has created this Calculator and 200+ more calculators!
Verified by Akshay Talbar
Vishwakarma University (VU), Pune
Akshay Talbar has verified this Calculator and 10+ more calculators!

4 Infinite Medium Calculators

Isothermal Ellipsoid Buried in Infinite Medium
Go Conduction Shape Factor = (4*pi*Semi Major Axis of Ellipse*sqrt(1-Semi Minor Axis of Ellipse/Semi Major Axis of Ellipse^2))/(atanh(sqrt(1-Semi Minor Axis of Ellipse/Semi Major Axis of Ellipse^2)))
Two parallel Isothermal Cylinders placed in Infinite medium
Go Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2))
Isothermal Cylinder in Midplane of Infinite wall
Go Conduction Shape Factor = (8*Distance from Surface to Centre of Object)/(pi*Diameter of Cylinder)
Isothermal Sphere Buried in Infinite Medium
Go Conduction Shape Factor = 4*pi*Radius of Sphere

Two parallel Isothermal Cylinders placed in Infinite medium Formula

Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2))
S = (2*pi*Lc)/acosh((4*d^2-D1^2-D2^2)/(2*D1*D2))

Why we use conduction shape factor?

Conduction shape factors are generally used when the geometries and configurations of the system are complex which makes the calculation of heat transfer very difficult.

How to Calculate Two parallel Isothermal Cylinders placed in Infinite medium?

Two parallel Isothermal Cylinders placed in Infinite medium calculator uses Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2)) to calculate the Conduction Shape Factor, Two parallel Isothermal Cylinders placed in Infinite medium formula give the shape factor when two parallel cylinders at some distance are placed in an infinite medium for heat conduction. Conduction Shape Factor is denoted by S symbol.

How to calculate Two parallel Isothermal Cylinders placed in Infinite medium using this online calculator? To use this online calculator for Two parallel Isothermal Cylinders placed in Infinite medium, enter Length of Cylinder (Lc), Distance Between Centers (d), Diameter of Cylinder 1 (D1) & Diameter of Cylinder 2 (D2) and hit the calculate button. Here is how the Two parallel Isothermal Cylinders placed in Infinite medium calculation can be explained with given input values -> 28.00001 = (2*pi*4)/acosh((4*10.1890145^2-5.1^2-13.739222^2)/(2*5.1*13.739222)).

FAQ

What is Two parallel Isothermal Cylinders placed in Infinite medium?
Two parallel Isothermal Cylinders placed in Infinite medium formula give the shape factor when two parallel cylinders at some distance are placed in an infinite medium for heat conduction and is represented as S = (2*pi*Lc)/acosh((4*d^2-D1^2-D2^2)/(2*D1*D2)) or Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2)). Length of Cylinder is the vertical height of the Cylinder, Distance between centers is the distance between two centers of circle, Diameter of Cylinder 1 is the diameter of the first cylinder & Diameter of Cylinder 2 is the diameter of the second cylinder.
How to calculate Two parallel Isothermal Cylinders placed in Infinite medium?
Two parallel Isothermal Cylinders placed in Infinite medium formula give the shape factor when two parallel cylinders at some distance are placed in an infinite medium for heat conduction is calculated using Conduction Shape Factor = (2*pi*Length of Cylinder)/acosh((4*Distance Between Centers^2-Diameter of Cylinder 1^2-Diameter of Cylinder 2^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2)). To calculate Two parallel Isothermal Cylinders placed in Infinite medium, you need Length of Cylinder (Lc), Distance Between Centers (d), Diameter of Cylinder 1 (D1) & Diameter of Cylinder 2 (D2). With our tool, you need to enter the respective value for Length of Cylinder, Distance Between Centers, Diameter of Cylinder 1 & Diameter of Cylinder 2 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Conduction Shape Factor?
In this formula, Conduction Shape Factor uses Length of Cylinder, Distance Between Centers, Diameter of Cylinder 1 & Diameter of Cylinder 2. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Conduction Shape Factor = 4*pi*Radius of Sphere
  • Conduction Shape Factor = (4*pi*Semi Major Axis of Ellipse*sqrt(1-Semi Minor Axis of Ellipse/Semi Major Axis of Ellipse^2))/(atanh(sqrt(1-Semi Minor Axis of Ellipse/Semi Major Axis of Ellipse^2)))
  • Conduction Shape Factor = (8*Distance from Surface to Centre of Object)/(pi*Diameter of Cylinder)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!