Van der Waals Constant given Inversion Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2)
a = ((Ti*[R]*b)/2)
This formula uses 1 Constants, 3 Variables
Constants Used
[R] - Universal gas constant Value Taken As 8.31446261815324
Variables Used
Van der Waals Constant a - (Measured in Pascal Square Kiloliter per Square Mole) - The Van der Waals Constant a depend upon the intermolecular force of attraction within the gas molecules.
Inversion Temperature - (Measured in Kelvin) - The Inversion Temperature is the temperature at which there is no heating or cooling of the gas.
Van der Waals Constant b - (Measured in Cubic Meter per Mole) - The Van der Waals Constant b along with the number of moles is the volume of the gas which is incompressible.
STEP 1: Convert Input(s) to Base Unit
Inversion Temperature: 100 Kelvin --> 100 Kelvin No Conversion Required
Van der Waals Constant b: 3 Liter per Mole --> 0.003 Cubic Meter per Mole (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
a = ((Ti*[R]*b)/2) --> ((100*[R]*0.003)/2)
Evaluating ... ...
a = 1.24716939272299
STEP 3: Convert Result to Output's Unit
1.24716939272299 Pascal Square Kiloliter per Square Mole --> No Conversion Required
FINAL ANSWER
1.24716939272299 1.247169 Pascal Square Kiloliter per Square Mole <-- Van der Waals Constant a
(Calculation completed in 00.020 seconds)

Credits

Created by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has created this Calculator and 700+ more calculators!
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

18 Van der Waals Constant Calculators

Van der Waals Constant b given Inversion Temperature and Boltzmann Constant
Go Van der Waals Constant b = (2*Van der Waals Constant a)/(Inversion Temperature*[BoltZ])
Van der Waals Constant given Inversion Temperature and Boltzmann Constant
Go Van der Waals Constant a = ((Inversion Temperature*Van der Waals Constant b*[BoltZ])/2)
Van der Waals Constant b given Critical Temperature
Go Van der Waals Constant b = (8*Van der Waals Constant a)/(27*Critical Temperature*[R])
Critical Temperature given Van der Waals Constants
Go Critical Temperature = (8*Van der Waals Constant a)/(27*Van der Waals Constant b*[R])
Van der Waals Constant b given Inversion Temperature
Go Van der Waals Constant b = (2*Van der Waals Constant a)/(Inversion Temperature*[R])
Van der Waals Constant given Inversion Temperature
Go Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2)
Van der Waals Constant given Critical Temperature
Go Van der Waals Constant a = (27*Van der Waals Constant b*[R]*Critical Temperature)/8
Van der Waals Constant b given Critical Pressure
Go Van der Waals Constant b = sqrt(Van der Waals Constant a/(27*Critical Pressure))
Van der Waals Constant b given Boyle Temperature
Go Van der Waals Constant b = (Van der Waals Constant a/([R]*Boyle Temperature))
Boyle Temperature given Vander Waal Constants
Go Boyle Temperature = (Van der Waals Constant a/([R]*Van der Waals Constant b))
Van der Waals Constant given Boyle Temperature
Go Van der Waals Constant a = (Boyle Temperature*[R]*Van der Waals Constant b)
Critical Temperature without use of Van der Waals Constant
Go Critical Temperature = (8/3)*((Critical Pressure*Critical Volume)/[R])
Critical Pressure without use of Van der Waals Constants
Go Critical Pressure = (3/8)*(([R]*Critical Temperature)/Critical Volume)
Critical Volume without use of Van der Waals Constant
Go Critical Volume = (3/8)*(([R]*Critical Temperature)/Critical Pressure)
Critical Pressure given Van der Waals Constants
Go Critical Pressure = (Van der Waals Constant a/(27*(Van der Waals Constant b)^2))
Van der Waals Constant given Critical Pressure
Go Van der Waals Constant a = (27*Critical Pressure*(Van der Waals Constant b)^2)
Van der Waals Constant b given Critical Volume
Go Van der Waals Constant b = (Critical Volume/3)
Critical Volume given Van der Waals Constant b
Go Critical Volume = (3*Van der Waals Constant b)

Van der Waals Constant given Inversion Temperature Formula

Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2)
a = ((Ti*[R]*b)/2)

What are the postulates of kinetic theory of gases?

1) Actual volume of gas molecules is negligible in comparison to the total volume of the gas. 2) no force of attraction between the gas molecules. 3) Particles of gas are in constant random motion. 4) Particles of gas collide with each other and with the walls of the container. 5)Collisions are perfectly elastic. 6) Different particles of the gas, have different speeds. 7) The average kinetic energy of the gas molecule is directly proportional to the absolute temperature.

How to Calculate Van der Waals Constant given Inversion Temperature?

Van der Waals Constant given Inversion Temperature calculator uses Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2) to calculate the Van der Waals Constant a, The Van der Waals constant given inversion temperature formula is defined as the product of inversion temperature and Vander Waal constant b to the universal gas constant. Van der Waals Constant a is denoted by a symbol.

How to calculate Van der Waals Constant given Inversion Temperature using this online calculator? To use this online calculator for Van der Waals Constant given Inversion Temperature, enter Inversion Temperature (Ti) & Van der Waals Constant b (b) and hit the calculate button. Here is how the Van der Waals Constant given Inversion Temperature calculation can be explained with given input values -> 1.247169 = ((100*[R]*0.003)/2).

FAQ

What is Van der Waals Constant given Inversion Temperature?
The Van der Waals constant given inversion temperature formula is defined as the product of inversion temperature and Vander Waal constant b to the universal gas constant and is represented as a = ((Ti*[R]*b)/2) or Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2). The Inversion Temperature is the temperature at which there is no heating or cooling of the gas & The Van der Waals Constant b along with the number of moles is the volume of the gas which is incompressible.
How to calculate Van der Waals Constant given Inversion Temperature?
The Van der Waals constant given inversion temperature formula is defined as the product of inversion temperature and Vander Waal constant b to the universal gas constant is calculated using Van der Waals Constant a = ((Inversion Temperature*[R]*Van der Waals Constant b)/2). To calculate Van der Waals Constant given Inversion Temperature, you need Inversion Temperature (Ti) & Van der Waals Constant b (b). With our tool, you need to enter the respective value for Inversion Temperature & Van der Waals Constant b and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Van der Waals Constant a?
In this formula, Van der Waals Constant a uses Inversion Temperature & Van der Waals Constant b. We can use 4 other way(s) to calculate the same, which is/are as follows -
  • Van der Waals Constant a = (Boyle Temperature*[R]*Van der Waals Constant b)
  • Van der Waals Constant a = (27*Critical Pressure*(Van der Waals Constant b)^2)
  • Van der Waals Constant a = (27*Van der Waals Constant b*[R]*Critical Temperature)/8
  • Van der Waals Constant a = ((Inversion Temperature*Van der Waals Constant b*[BoltZ])/2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!