Volume of Conductor Material using Constant(DC 3-Wire) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Conductor = (5)*Constant Overhead DC/(16)
V = (5)*K/(16)
This formula uses 2 Variables
Variables Used
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line.
Constant Overhead DC - Constant Overhead DC is defined as the constant of line of a Overhead supply system.
STEP 1: Convert Input(s) to Base Unit
Constant Overhead DC: 7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = (5)*K/(16) --> (5)*7/(16)
Evaluating ... ...
V = 2.1875
STEP 3: Convert Result to Output's Unit
2.1875 Cubic Meter --> No Conversion Required
FINAL ANSWER
2.1875 Cubic Meter <-- Volume of Conductor
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

16 Wire Parameters Calculators

Line Losses using Constant(DC 3-Wire)
Go Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*(Maximum Voltage Overhead DC)^2))
Constant(DC 3-Wire)
Go Constant Overhead DC = ((4)*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Line Losses*(Maximum Voltage Overhead DC))
Line Losses using Volume of Conductor Material (DC 3-Wire)
Go Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2))
Line Losses using Area of X-Section(DC 3-Wire)
Go Line Losses = ((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*(Maximum Voltage Overhead DC^2)))
Volume of Conductor Material (DC 3-Wire)
Go Volume of Conductor = ((2.5)*2)*(Current Overhead DC^2)*Resistivity*(Length of Wire DC^2)/Line Losses
Length using Line Losses(DC 3-Wire)
Go Length of Wire DC = Line Losses*Area of Overhead DC Wire/(2*(Current Overhead DC^2)*Resistivity)
Area of X-Section(DC 3-Wire)
Go Area of Overhead DC Wire = (2*(Current Overhead DC^2)*Resistivity*Length of Wire DC)/Line Losses
Area of X-Section using Line Losses(DC 3-Wire)
Go Area of Overhead DC Wire = ((Current Overhead DC^2)*Resistivity)*Length of Wire DC/Line Losses
Length using Area of X-Section(DC 3-Wire)
Go Length of Wire DC = Area of Overhead DC Wire*Line Losses/((Current Overhead DC^2)*Resistivity)
Area of X-Section using Volume of Conductor Material (DC 3-Wire)
Go Area of Overhead DC Wire = Volume of Conductor/((2.5)*Length of Wire DC)
Length using Volume of Conductor Material (DC 3-Wire)
Go Length of Wire DC = Volume of Conductor/((2.5)*Area of Overhead DC Wire)
Volume of Conductor Material using Area of X-Section(DC 3-Wire)
Go Volume of Conductor = (2.5)*Area of Overhead DC Wire*Length of Wire DC
Length using Constant(DC 3-Wire)
Go Length of Wire DC = Constant Overhead DC/Area of Overhead DC Wire
Line Losses(DC 3-Wire)
Go Line Losses = 2*(Current Overhead DC^2)*Resistance Overhead DC
Volume of Conductor Material using Constant(DC 3-Wire)
Go Volume of Conductor = (5)*Constant Overhead DC/(16)
Constant using Volume of Conductor Material (DC 3-Wire)
Go Constant Overhead DC = Volume of Conductor*(16/5)

Volume of Conductor Material using Constant(DC 3-Wire) Formula

Volume of Conductor = (5)*Constant Overhead DC/(16)
V = (5)*K/(16)

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Volume of Conductor Material using Constant(DC 3-Wire)?

Volume of Conductor Material using Constant(DC 3-Wire) calculator uses Volume of Conductor = (5)*Constant Overhead DC/(16) to calculate the Volume of Conductor, The Volume of Conductor Material using Constant(DC 3-wire) formula is defined as the 3-dimensional space enclosed by a boundary or occupied by an object. Volume of Conductor is denoted by V symbol.

How to calculate Volume of Conductor Material using Constant(DC 3-Wire) using this online calculator? To use this online calculator for Volume of Conductor Material using Constant(DC 3-Wire), enter Constant Overhead DC (K) and hit the calculate button. Here is how the Volume of Conductor Material using Constant(DC 3-Wire) calculation can be explained with given input values -> 2.1875 = (5)*7/(16).

FAQ

What is Volume of Conductor Material using Constant(DC 3-Wire)?
The Volume of Conductor Material using Constant(DC 3-wire) formula is defined as the 3-dimensional space enclosed by a boundary or occupied by an object and is represented as V = (5)*K/(16) or Volume of Conductor = (5)*Constant Overhead DC/(16). Constant Overhead DC is defined as the constant of line of a Overhead supply system.
How to calculate Volume of Conductor Material using Constant(DC 3-Wire)?
The Volume of Conductor Material using Constant(DC 3-wire) formula is defined as the 3-dimensional space enclosed by a boundary or occupied by an object is calculated using Volume of Conductor = (5)*Constant Overhead DC/(16). To calculate Volume of Conductor Material using Constant(DC 3-Wire), you need Constant Overhead DC (K). With our tool, you need to enter the respective value for Constant Overhead DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume of Conductor?
In this formula, Volume of Conductor uses Constant Overhead DC. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume of Conductor = ((2.5)*2)*(Current Overhead DC^2)*Resistivity*(Length of Wire DC^2)/Line Losses
  • Volume of Conductor = (2.5)*Area of Overhead DC Wire*Length of Wire DC
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!