Volume of Core in Short Axially Loaded Columns with Helical Ties Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement
Vc = (pi/4)*dc^(2)*P
This formula uses 1 Constants, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Volume of Core - (Measured in Cubic Meter) - Volume of core is the volume of the core of a given spiral reinforcement.
Diameter of Core - (Measured in Millimeter) - Diameter of core is the diameter of the core of a given spiral reinforcement.
Pitch of Spiral Reinforcement - (Measured in Millimeter) - Pitch of Spiral Reinforcement gives us a certain amount of flexural reinforcement.
STEP 1: Convert Input(s) to Base Unit
Diameter of Core: 150 Millimeter --> 150 Millimeter No Conversion Required
Pitch of Spiral Reinforcement: 10 Millimeter --> 10 Millimeter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vc = (pi/4)*dc^(2)*P --> (pi/4)*150^(2)*10
Evaluating ... ...
Vc = 176714.586764426
STEP 3: Convert Result to Output's Unit
176714.586764426 Cubic Meter --> No Conversion Required
FINAL ANSWER
176714.586764426 176714.6 Cubic Meter <-- Volume of Core
(Calculation completed in 00.004 seconds)

Credits

Created by Pranav More
Vellore Institute of Technology, Vellore (VIT, Vellore), Vellore
Pranav More has created this Calculator and 10+ more calculators!
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

12 Short Axially Loaded Columns with Helical Ties Calculators

Area of Longitudinal Reinforcement for Columns given Factored Axial Load in Spiral Columns
Go Area of Steel Reinforcement = (((Factored Load)/(1.05))-(0.4*Characteristic Compressive Strength*Area of Concrete))/(0.67*Characteristic Strength of Steel Reinforcement)
Characteristic Strength of Compression Reinforcement given Factored Load in Spiral Columns
Go Characteristic Strength of Steel Reinforcement = ((Factored Load/1.05)-(0.4*Characteristic Compressive Strength*Area of Concrete))/(0.67*Area of Steel Reinforcement)
Characteristic Compressive Strength of Concrete given Factored Axial Load in Spiral Columns
Go Characteristic Compressive Strength = ((Factored Load/1.05)-0.67*Characteristic Strength of Steel Reinforcement*Area of Steel Reinforcement)/(0.4*Area of Concrete)
Area of Concrete given Factored Axial Load
Go Area of Concrete = ((Factored Load/1.05)-0.67*Characteristic Strength of Steel Reinforcement*Area of Steel Reinforcement)/(0.4*Characteristic Compressive Strength)
Factored Axial Load on Member of Spiral Columns
Go Factored Load = 1.05*(0.4*Characteristic Compressive Strength*Area of Concrete+0.67*Characteristic Strength of Steel Reinforcement*Area of Steel Reinforcement)
Diameter of Spiral Reinforcement given Volume of Helical Reinforcement in one Loop
Go Diameter of Spiral Reinforcement = Diameter of Core-((Volume of Helical Reinforcement)/(pi*Area of Steel Reinforcement))
Diameter of Core given Volume of Helical Reinforcement in One Loop
Go Diameter of Core = ((Volume of Helical Reinforcement)/(pi*Area of Steel Reinforcement))+Diameter of Spiral Reinforcement
Area of Cross-section of Spiral Reinforcement given Volume
Go Area of Steel Reinforcement = Volume of Helical Reinforcement/(pi*(Diameter of Core-Diameter of Spiral Reinforcement))
Volume of Helical Reinforcement in One Loop
Go Volume of Helical Reinforcement = pi*(Diameter of Core-Diameter of Spiral Reinforcement)*Area of Steel Reinforcement
Diameter of Core given Volume of Core
Go Diameter of Core = sqrt(4*Volume of Core/(pi*Pitch of Spiral Reinforcement))
Volume of Core in Short Axially Loaded Columns with Helical Ties
Go Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement
Pitch of Spiral Reinforcement given Volume of Core
Go Pitch of Spiral Reinforcement = (4*Volume of Core)/(pi*Diameter of Core^2)

Volume of Core in Short Axially Loaded Columns with Helical Ties Formula

Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement
Vc = (pi/4)*dc^(2)*P

What is a Short Column?

When the length of the column is less as compared to its c/s dimension, it is called the Short column. A short column is the one whose ratio of effective length to its least lateral dimension is less than or equal to 12.

How to Calculate Volume of Core in Short Axially Loaded Columns with Helical Ties?

Volume of Core in Short Axially Loaded Columns with Helical Ties calculator uses Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement to calculate the Volume of Core, The Volume of Core in Short Axially Loaded Columns with Helical Ties formula is defined as the volume of the core of the given column. Volume of Core is denoted by Vc symbol.

How to calculate Volume of Core in Short Axially Loaded Columns with Helical Ties using this online calculator? To use this online calculator for Volume of Core in Short Axially Loaded Columns with Helical Ties, enter Diameter of Core (dc) & Pitch of Spiral Reinforcement (P) and hit the calculate button. Here is how the Volume of Core in Short Axially Loaded Columns with Helical Ties calculation can be explained with given input values -> 176714.6 = (pi/4)*0.15^(2)*0.01.

FAQ

What is Volume of Core in Short Axially Loaded Columns with Helical Ties?
The Volume of Core in Short Axially Loaded Columns with Helical Ties formula is defined as the volume of the core of the given column and is represented as Vc = (pi/4)*dc^(2)*P or Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement. Diameter of core is the diameter of the core of a given spiral reinforcement & Pitch of Spiral Reinforcement gives us a certain amount of flexural reinforcement.
How to calculate Volume of Core in Short Axially Loaded Columns with Helical Ties?
The Volume of Core in Short Axially Loaded Columns with Helical Ties formula is defined as the volume of the core of the given column is calculated using Volume of Core = (pi/4)*Diameter of Core^(2)*Pitch of Spiral Reinforcement. To calculate Volume of Core in Short Axially Loaded Columns with Helical Ties, you need Diameter of Core (dc) & Pitch of Spiral Reinforcement (P). With our tool, you need to enter the respective value for Diameter of Core & Pitch of Spiral Reinforcement and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!