Volume of Each Grit Chamber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume = (Peak flow rate*Detention time)/(7.48*24*60)
VT = (Qp*Td)/(7.48*24*60)
This formula uses 3 Variables
Variables Used
Volume - (Measured in Cubic Meter) - Volume is the amount of space that a substance or object occupies or that is enclosed within a container.
Peak flow rate - (Measured in Cubic Meter per Second) - Peak flow rate is defined as volumetric flow rate of peak flow.
Detention time - (Measured in Second) - Detention time is the length of time water is retained in a vessel or basin.
STEP 1: Convert Input(s) to Base Unit
Peak flow rate: 5 Cubic Meter per Second --> 5 Cubic Meter per Second No Conversion Required
Detention time: 3 Minute --> 180 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VT = (Qp*Td)/(7.48*24*60) --> (5*180)/(7.48*24*60)
Evaluating ... ...
VT = 0.0835561497326203
STEP 3: Convert Result to Output's Unit
0.0835561497326203 Cubic Meter --> No Conversion Required
FINAL ANSWER
0.0835561497326203 0.083556 Cubic Meter <-- Volume
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Volume of Each Grit Chamber Formula

Volume = (Peak flow rate*Detention time)/(7.48*24*60)
VT = (Qp*Td)/(7.48*24*60)

What is detention time ?

Detention time is the length of time water is retained in a vessel or basin or the period from the time the water enters a settling basin until it flows out the other end. When calculating unit process detention times, we are calculating the length of time it takes the water to flow through that unit process.

How to Calculate Volume of Each Grit Chamber?

Volume of Each Grit Chamber calculator uses Volume = (Peak flow rate*Detention time)/(7.48*24*60) to calculate the Volume, The Volume of Each Grit Chamber calculates the volume of each grit chamber when we have prior information of peak flow rate and detention time . Volume is denoted by VT symbol.

How to calculate Volume of Each Grit Chamber using this online calculator? To use this online calculator for Volume of Each Grit Chamber, enter Peak flow rate (Qp) & Detention time (Td) and hit the calculate button. Here is how the Volume of Each Grit Chamber calculation can be explained with given input values -> 0.083556 = (5*180)/(7.48*24*60).

FAQ

What is Volume of Each Grit Chamber?
The Volume of Each Grit Chamber calculates the volume of each grit chamber when we have prior information of peak flow rate and detention time and is represented as VT = (Qp*Td)/(7.48*24*60) or Volume = (Peak flow rate*Detention time)/(7.48*24*60). Peak flow rate is defined as volumetric flow rate of peak flow & Detention time is the length of time water is retained in a vessel or basin.
How to calculate Volume of Each Grit Chamber?
The Volume of Each Grit Chamber calculates the volume of each grit chamber when we have prior information of peak flow rate and detention time is calculated using Volume = (Peak flow rate*Detention time)/(7.48*24*60). To calculate Volume of Each Grit Chamber, you need Peak flow rate (Qp) & Detention time (Td). With our tool, you need to enter the respective value for Peak flow rate & Detention time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume?
In this formula, Volume uses Peak flow rate & Detention time. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
  • Volume = Assumed grit quantity*Volumetric Flow Rate
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!