Wall Temperature of Fluid over Flat Plate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature
Tw = ρe/ρw*Tstatic
This formula uses 4 Variables
Variables Used
Temperature of wall in Kelvin - (Measured in Kelvin) - Temperature of wall in Kelvin is the wall temperature of the body under a flow.
Static density - (Measured in Kilogram per Cubic Meter) - Static density, is the density of the fluid when its not moving, or the density of fluid if we are moving relative to the fluid.
Wall Density - (Measured in Kilogram per Cubic Meter) - Wall Density is the variable considered under turbulent conditions as the density varies near the wall under high viscous flows.
Static Temperature - (Measured in Kelvin) - The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
STEP 1: Convert Input(s) to Base Unit
Static density: 100 Kilogram per Cubic Meter --> 100 Kilogram per Cubic Meter No Conversion Required
Wall Density: 14 Kilogram per Cubic Meter --> 14 Kilogram per Cubic Meter No Conversion Required
Static Temperature: 350 Kelvin --> 350 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Tw = ρew*Tstatic --> 100/14*350
Evaluating ... ...
Tw = 2500
STEP 3: Convert Result to Output's Unit
2500 Kelvin --> No Conversion Required
FINAL ANSWER
2500 Kelvin <-- Temperature of wall in Kelvin
(Calculation completed in 00.004 seconds)

Credits

Created by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has created this Calculator and 300+ more calculators!
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has verified this Calculator and 300+ more calculators!

4 Wall Temperature Calculators

Wall Temperature of Plate using Wall Viscosity
Go Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity
Wall Temperature over Flat Plate using Static Mach Number
Go Wall Temperature = Static Temperature*Mach Number^2*(1+(Specific Heat Ratio-1)/2)
Wall Temperature over Flat Plate under Viscous, Very High Mach Flow
Go Wall Temperature = Static Temperature*((Specific Heat Ratio-1)/2)*Mach Number^2
Wall Temperature of Fluid over Flat Plate
Go Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature

Wall Temperature of Fluid over Flat Plate Formula

Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature
Tw = ρe/ρw*Tstatic

What is density?

Density is a measure of mass per volume. The average density of an object equals its total mass divided by its total volume.

How to Calculate Wall Temperature of Fluid over Flat Plate?

Wall Temperature of Fluid over Flat Plate calculator uses Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature to calculate the Temperature of wall in Kelvin, The Wall temperature of fluid over flat plate formula is defined as the product of static temperature to the ratio of wall and static density. Temperature of wall in Kelvin is denoted by Tw symbol.

How to calculate Wall Temperature of Fluid over Flat Plate using this online calculator? To use this online calculator for Wall Temperature of Fluid over Flat Plate, enter Static density e), Wall Density w) & Static Temperature (Tstatic) and hit the calculate button. Here is how the Wall Temperature of Fluid over Flat Plate calculation can be explained with given input values -> 2500 = 100/14*350.

FAQ

What is Wall Temperature of Fluid over Flat Plate?
The Wall temperature of fluid over flat plate formula is defined as the product of static temperature to the ratio of wall and static density and is represented as Tw = ρew*Tstatic or Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature. Static density, is the density of the fluid when its not moving, or the density of fluid if we are moving relative to the fluid, Wall Density is the variable considered under turbulent conditions as the density varies near the wall under high viscous flows & The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
How to calculate Wall Temperature of Fluid over Flat Plate?
The Wall temperature of fluid over flat plate formula is defined as the product of static temperature to the ratio of wall and static density is calculated using Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature. To calculate Wall Temperature of Fluid over Flat Plate, you need Static density e), Wall Density w) & Static Temperature (Tstatic). With our tool, you need to enter the respective value for Static density, Wall Density & Static Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Temperature of wall in Kelvin?
In this formula, Temperature of wall in Kelvin uses Static density, Wall Density & Static Temperature. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!